ArticleAnalytical chemistry2018
Dual-Color Bioluminescent Sensor Proteins for Therapeutic Drug Monitoring of Antitumor Antibodies.
Article in Analytical chemistry, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed, 52 citations in OpenAlex.
- Modular Input-Output Biosensor Design UsingACS sensors · 2026Article
- Multiepitope recognition technology promotes the in-depth analysis of antibody‒drug conjugates.Acta pharmaceutica Sinica. B · 2024Article
- Bioluminescent detection of viral surface proteins using branched multivalent protein switches.RSC chemical biology · 2024Article
- Therapeutic drug monitoring of immunotherapies with novel Affimer-NanoBiT sensor construct.Sensors & diagnostics · 2024Article
- Enzyme - Switch sensors for therapeutic drug monitoring of immunotherapies.Biosensors & bioelectronics · 2023Article
- Development of an Anti-Idiotype Aptamer-Based Electrochemical Sensor for a Humanized Therapeutic Antibody Monitoring.International journal of molecular sciences · 2023Article
- Bioluminescence Goes Dark: Boosting the Performance of Bioluminescent Sensor Proteins Using Complementation Inhibitors.ACS sensors · 2022Article
- Developments in FRET- and BRET-Based Biosensors.Micromachines · 2022Review
- Protein sensors combining both on-and-off model for antibody homogeneous assay.Biosensors & bioelectronics · 2022Article
- Technologies for Frugal and Sensitive Point-of-Care Immunoassays.Annual review of analytical chemistry (Palo Alto, Calif.) · 2022Review
- A Bioluminescent Sensor for Rapid Detection of PPEP-1, aSensors (Basel, Switzerland) · 2021Article
- A plug-and-play platform of ratiometric bioluminescent sensors for homogeneous immunoassays.Nature communications · 2021Article
- Article
- Resonance Energy Transfer-Based Biosensors for Point-of-Need Diagnosis-Progress and Perspectives.Sensors (Basel, Switzerland) · 2021Review
- Recent progress in the molecular imaging of therapeutic monoclonal antibodies.Journal of pharmaceutical analysis · 2020Review
- Recent Progress in Optical Sensors for Biomedical Diagnostics.Micromachines · 2020Review
- iFLinkC: an iterative functional linker cloning strategy for the combinatorial assembly and recombination of linker peptides with functional domains.Nucleic acids research · 2020Article
- Transmembrane signaling on a protocell: Creation of receptor-enzyme chimeras for immunodetection of specific antibodies and antigens.Scientific reports · 2019Article
- Ratiometric BRET Measurements of ATP with a Genetically-Encoded Luminescent Sensor.Sensors (Basel, Switzerland) · 2019Article
- Development and Applications of Bioluminescent and Chemiluminescent Reporters and Biosensors.Annual review of analytical chemistry (Palo Alto, Calif.) · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
Abstract
Monitoring the levels of therapeutic antibodies in individual patients would allow patient-specific dose optimization, with the potential for major therapeutic and financial benefits. Our group recently developed a new platform of bioluminescent sensor proteins (LUMABS; LUMinescent AntiBody Sensor) that allow antibody detection directly in blood plasma. In this study, we targeted four clinically important therapeutic antibodies, the Her2-receptor targeting trastuzumab, the anti-CD20 antibodies rituximab and obinutuzumab, and the EGFR-blocking cetuximab. A strong correlation was found between the affinity of the antibody binding peptide and sensor performance. LUMABS sensors with physiologically relevant affinities and decent sensor responses were obtained for trastuzumab and cetuximab using mimotope and meditope peptides, respectively, with affinities in the 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.