Evidence map›Paper›PMID 29442163›Full record

ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2018

Accuracy and feasibility of a dedicated image guidance solution for endoscopic lateral skull base surgery.

Christoph Rathgeb, Lukas Anschuetz, Daniel Schneider, Cilgia Dür, Marco Caversaccio, Stefan Weber, Tom Williamson

Abstract read
PubMed Publisher
In one paragraph

Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Integration of Trackerless Surface Reconstruction-Based Surgical Navigation With Exoscopic Trans-Mastoid Surgery.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2026
    Article
  3. Automated objective surgical planning for lateral skull base tumors.International journal of computer assisted radiology and surgery · 2022
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Christoph RathgebARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Lukas AnschuetzDepartment of Otorhinolaryngology, Head and Neck Surgery, Inselspital, University Hospital and University of Bern, Bern, Switzerland. anschuetz.lukas@gmail.com.ORCID http://orcid.org/0000-0001-6927-0664
Daniel SchneiderARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Cilgia DürDepartment of Otorhinolaryngology, Head and Neck Surgery, Inselspital, University Hospital and University of Bern, Bern, Switzerland.
Marco CaversaccioDepartment of Otorhinolaryngology, Head and Neck Surgery, Inselspital, University Hospital and University of Bern, Bern, Switzerland.
Stefan WeberARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.
Tom WilliamsonARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.

Funding

Universität Bern CTU-grant 2017-01
6 · The paper itself

Abstract

objectiveWe aimed to design, build and validate a surgical navigation system which fulfills the accuracy requirements for surgical procedures on the ear and the lateral skull base, and which integrates with the endoscopic workflow and operating room setup. MATERIALS AND

methodsThe navigation system consists of portable tablet computer (iPad Pro, Apple Computer, USA) and an optical tracking system (Cambar B1, Axios3D, Germany), both connected via a wireless Bluetooth link and attached directly to the OR table. Active optical tracking references are rigidly fixed to both the patient and surgical tools. Software to support image import, registration and 2D/3D visualization has been developed. Two models were used for targeting accuracy assessment: a technical phantom model and an ex vivo temporal bone model. Additionally, workflow integration and usability of the navigation system during endoscopic lateral skull base procedures was investigated in ex vivo experiments on 12 sides of cadaver head specimens.

resultsThe accuracy experiments revealed a target registration error in the technical phantom model of 0.20 ± 0.10 mm (n = 36) and during the ex vivo assessment of 0.28 ± 0.10 mm (n = 21). Navigation was successfully carried out in n = 36 procedures (infracochlear, suprageniculate and transpromontorial approach), with navigated instruments usable without interference with the endoscope. The system aided in the successful and accurate identification of vital anatomical structures.

conclusionsUseful surgical navigation is, to a large extent, a result of sufficiently accurate tracking technology. We have demonstrated sufficient accuracy and a potentially suitable integration for surgical application within endoscopic lateral skull base procedures.

Indexed as

CadaverComputers, HandheldEndoscopyFeasibility StudiesHumansImaging, Three-DimensionalNeurosurgical ProceduresSkull BaseSurgery, Computer-AssistedEndoscopic ear surgeryEndoscopic lateral skull base surgeryImage-guided therapyLateral skull baseNavigation

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.