Evidence map›Paper›PMID 29438344›Full record

ArticleSensors (Basel, Switzerland)2018

Evaluation of a Multichannel Non-Contact ECG System and Signal Quality Algorithms for Sleep Apnea Detection and Monitoring.

Ivan D Castro, Carolina Varon, Tom Torfs, Sabine Van Huffel, Robert Puers, Chris Van Hoof

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed, 1 pooled it
4.8field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed, 1 synthesis or guideline pooled it, 53 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Robustness of electrocardiogram signal quality indices.Journal of the Royal Society, Interface · 2022
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Ivan D CastroKU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium. ivand.castro@imec.be.ORCID 0000-0002-3852-2379
Carolina VaronKU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium. carolina.varon@esat.kuleuven.be.
Tom TorfsIMEC Belgium, 3001 Leuven, Belgium. tom.torfs@imec.be.ORCID 0000-0002-1302-3346
Sabine Van HuffelKU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium. sabine.vanhuffel@esat.kuleuven.be.ORCID 0000-0001-5939-0996
Robert PuersKU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium. puers@esat.kuleuven.be.ORCID 0000-0003-3415-2275
Chris Van HoofKU Leuven, Deptartment of Electrical Engineering-ESAT, 3001 Leuven, Belgium. chris.vanhoof@imec.be.
IMEC · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Sleep-related conditions require high-cost and low-comfort diagnosis at the hospital during one night or longer. To overcome this situation, this work aims to evaluate an unobtrusive monitoring technique for sleep apnea. This paper presents, for the first time, the evaluation of contactless capacitively-coupled electrocardiography (ccECG) signals for the extraction of sleep apnea features, together with a comparison of different signal quality indicators. A multichannel ccECG system is used to collect signals from 15 subjects in a sleep environment from different positions. Reference quality labels were assigned for every 30-s segment. Quality indicators were calculated, and their signal classification performance was evaluated. Features for the detection of sleep apnea were extracted from capacitive and reference signals. Sleep apnea features related to heart rate and heart rate variability achieved high similarity to the reference values, with

Indexed as

ElectrocardiographyAlgorithmsHeart RateHumansRespirationSignal Processing, Computer-AssistedSleep Apnea Syndromescapacitive ECGECG quality indicatornon-contact ECGsleep apneasleep monitoringunobtrusive monitoring

Identifiers

PMID29438344
PMCPMC5855940
OpenAlexW2793898907

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked