Evidence map›Paper›PMID 29435671›Full record

ArticleEJNMMI research2018

A new SPECT/CT reconstruction algorithm: reliability and accuracy in clinical routine for non-oncologic bone diseases.

Olivier Delcroix, Philippe Robin, Maelenn Gouillou, Alexandra Le Duc-Pennec, Zarrin Alavi, Pierre-Yves Le Roux, Ronan Abgral, Pierre-Yves Salaun, David Bourhis, Solène Querellou

Abstract read
In one paragraph

Article in EJNMMI research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. The value ofQuantitative imaging in medicine and surgery · 2025
    Article
  3. Review
  4. Article
  5. Article
  6. Cardiac DPD-uptake time dependency in ATTR patients verified by quantitative SPECT/CT and semiquantitative planar parameters.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. QuantitativeJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2020
    Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Olivier DelcroixNuclear Medicine Department, CHRU Hospital Morvan, Brest, France.
Philippe RobinNuclear Medicine Department, CHRU Hospital Morvan, Brest, France.
Maelenn GouillouCHRU Brest, Brest, France.
Alexandra Le Duc-PennecNuclear Medicine Department, CHRU Hospital Morvan, Brest, France.
Zarrin AlaviBrest Medical University Hospital-Inserm CIC 1412, Brest, France.
Pierre-Yves Le RouxNuclear Medicine Department, CHRU Hospital Morvan, Brest, France.
Ronan AbgralNuclear Medicine Department, CHRU Hospital Morvan, Brest, France.
Pierre-Yves SalaunNuclear Medicine Department, CHRU Hospital Morvan, Brest, France.
David BourhisNuclear Medicine Department, CHRU Hospital Morvan, Brest, France.
Solène QuerellouNuclear Medicine Department, CHRU Hospital Morvan, Brest, France. solene.querellou@chu-brest.fr.ORCID http://orcid.org/0000-0002-4525-2696

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundxSPECT Bone® (xB) is a new reconstruction algorithm developed by Siemens® in bone hybrid imaging (SPECT/CT). A CT-based tissue segmentation is incorporated into SPECT reconstruction to provide SPECT images with bone anatomy appearance. The objectives of this study were to assess xB/CT reconstruction diagnostic reliability and accuracy in comparison with Flash 3D® (F3D)/CT in clinical routine. Two hundred thirteen consecutive patients referred to the Brest Nuclear Medicine Department for non-oncological bone diseases were evaluated retrospectively. Two hundred seven SPECT/CT were included. All SPECT/CT were independently interpreted by two nuclear medicine physicians (a junior and a senior expert) with xB/CT then with F3D/CT three months later. Inter-observer agreement (IOA) and diagnostic confidence were determined using McNemar test, and unweighted Kappa coefficient. The study objectives were then re-assessed for validation through > 18 months of clinical and paraclinical follow-up.

resultsNo statistically significant differences between IOA

conclusionsxB reconstruction algorithm was found reliable, providing high interobserver agreement and similar diagnostic confidence to F3D reconstruction in clinical routine.

Indexed as

Bone diseasesDiagnostic accuracyReconstruction algorithmScintigraphySPECT/CTxSPECT Bone®

Identifiers

PMID29435671
PMCPMC5809627

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked