ArticleThe Kobe journal of medical sciences2018
Evaluation of a Small Animal Irradiation System for Animal Experiments Using EBT3 Model GAFCHROMIC™ Film.
Article in The Kobe journal of medical sciences, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Amelioration of Radiation Enteropathy by Dietary Supplementation With Reduced Coenzyme Q10.Advances in radiation oncologyArticle
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In cancer research, small animal models, for example, mice, rats, or rabbits, facilitate the in-depth study of biological processes and the effects of radiation treatment that can lead to breakthrough discoveries. However, the physical quality of small animal irradiation systems has not been previously evaluated. In this study, we evaluate the quality of a small animal irradiation system using GAFCHROMIC™ film and a Tough Water Phantom. The profiles and percentage depth dose curves for several irradiation conditions were measured to evaluate the quality of the irradiation system. The symmetry ratios when the table was rotated were 1.1 (no filter), 1.0 (0.5 mm Al filter), 1.0 (1.0 mm Al filter), 1.1 (2 mm Al filter), and 1.0 (filter consisting of 0.5 mm Al combined with 0.1 mm Cu). The results of measuring the percentage depth dose curve showed that the relative doses were 17.5% (10 mm depth), 12.4% (20 mm depth), 9.5% (30 mm depth), and 7.4% (40 mm filter) with no filters inserted, 78.0% (10 mm depth), 61.1% (20 mm depth), 46.9% (30 mm depth), and 35.3% (40 mm depth) when a 1.0 mm Al filter was inserted, and 94.4% (10 mm depth), 81.7% (20 mm depth), 68.1% (30 mm depth), and 54.7% (40 mm depth) when a filter consisting of 1.0 mm Al combined with 0.2 mm Cu was inserted. These physical assessments seem to be necessary especially in vivo experiments because those increase reliability of data obtained from small animal irradiation systems.
Indexed as
Identifiers
29434180PMC5826025What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.