ArticleOrthopaedic surgery2018
Clinical Gait Evaluation of Patients with Lumbar Spine Stenosis.
Article in Orthopaedic surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 22 citations in OpenAlex.
- The role of wearable devices and objective gait analysis for the assessment and monitoring of patients with lumbar spinal stenosis: systematic review.BMC musculoskeletal disorders · 2019Pooled it
- Normative Database of Spatiotemporal Gait Metrics Across Age Groups: An Observational Case-Control Study.Sensors (Basel, Switzerland) · 2025Observational
- Lower Limb Muscle Fatigue Alters Spatiotemporal Gait Parameters and Turning Difficulty Characteristics in Parkinson's Disease.Annals of rehabilitation medicine · 2023Article
- Gait analysis using digital biomarkers including smart shoes in lumbar spinal canal stenosis: a scoping review.Frontiers in medicine · 2023Article
- Effect of pregnancy on female gait characteristics: a pilot study based on portable gait analyzer and induced acceleration analysis.Frontiers in physiology · 2023Article
- The Influence of a Shoe's Heel-Toe Drop on Gait Parameters during the Third Trimester of Pregnancy.Bioengineering (Basel, Switzerland) · 2022Article
- Analysing gait patterns in degenerative lumbar spine diseases: a literature review.Journal of spine surgery (Hong Kong) · 2022Review
- Quantitative Gait Analysis of Patients with Severe Symptomatic Spinal Stenosis Utilizing the Gait Profile Score: An Observational Clinical Study.Sensors (Basel, Switzerland) · 2022Observational
- Article
- A Multicenter Evaluation of the Feasibility, Patient/Provider Satisfaction, and Value of Virtual Spine Consultation During the COVID-19 Pandemic.World neurosurgery · 2021Article
- Objectifying clinical gait assessment: using a single-point wearable sensor to quantify the spatiotemporal gait metrics of people with lumbar spinal stenosis.Journal of spine surgery (Hong Kong) · 2021Article
- Impact of Sarcopenia on Clinical Outcomes of Minimally Invasive Lumbar Decompression Surgery.Scientific reports · 2019Article
- Objective monitoring of activity and Gait Velocity using wearable accelerometer following lumbar microdiscectomy to detect recurrent disc herniation.Journal of spine surgery (Hong Kong) · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 4 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe third generation Intelligent Device for Energy Expenditure and Activity (IDEEA3, MiniSun, CA) has been developed for clinical gait evaluation, and this study was designed to evaluate the accuracy and reliability of IDEEA3 for the gait measurement of lumbar spinal stenosis (LSS) patients.
methodsTwelve healthy volunteers were recruited to compare gait cycle, cadence, step length, velocity, and number of steps between a motion analysis system and a high-speed video camera. Twenty hospitalized LSS patients were recruited for the comparison of the five parameters between the IDEEA3 and GoPro camera. Paired t-test, intraclass correlation coefficient, concordance correlation coefficient, and Bland-Altman plots were used for the data analysis.
resultsThe ratios of GoPro camera results to motion analysis system results, and the ratios of IDEEA3 results to GoPro camera results were all around 1.00. All P-values of paired t-tests for gait cycle, cadence, step length, and velocity were greater than 0.05, while all the ICC and CCC results were above 0.950 with P < 0.001.
conclusionsThe measurements for gait cycle, cadence, step length, velocity, and number of steps with the GoPro camera are highly consistent with the measurements with the motion analysis system. The measurements for IDEEA3 are consistent with those for the GoPro camera. IDEEA3 can be effectively used in the gait measurement of LSS patients.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.