Evidence map›Paper›PMID 29430473›Full record

ArticleJournal of medical imaging (Bellingham, Wash.)2018

Dose and diagnostic performance comparison between phase-contrast mammography with synchrotron radiation and digital mammography: a clinical study report.

Christian Fedon, Luigi Rigon, Fulvia Arfelli, Diego Dreossi, Elisa Quai, Maura Tonutti, Giuliana Tromba, Maria Assunta Cova, Renata Longo

Open access · greenAbstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
5.3field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Christian FedonIstituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste, Italy.ORCID https://orcid.org/0000-0002-5998-453X
Luigi RigonIstituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste, Italy.ORCID https://orcid.org/0000-0001-5051-1851
Fulvia ArfelliIstituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste, Italy.
Diego DreossiElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Trieste, Italy.
Elisa QuaiUniversity of Trieste, Department of Physics, Trieste, Italy.
Maura TonuttiAzienda Sanitaria Universitaria Integrata di Trieste, Department of Radiology, Trieste, Italy.
Giuliana TrombaElettra-Sincrotrone Trieste S.C.p.A., Basovizza, Trieste, Italy.
Maria Assunta CovaAzienda Sanitaria Universitaria Integrata di Trieste, Department of Radiology, Trieste, Italy.
Renata LongoIstituto Nazionale di Fisica Nucleare, Sezione di Trieste, Trieste, Italy.
Elettra-Sincrotrone Trieste S.C.p.A. · ITUniversity of Trieste · ITAzienda Sanitaria Universitaria Integrata di Trieste · ITIstituto Nazionale di Fisica Nucleare, Sezione di Trieste · ITRadboud University Nijmegen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Two dosimetric quantities [mean glandular dose (MGD) and entrance surface air kerma (ESAK)] and the diagnostic performance of phase-contrast mammography with synchrotron radiation (MSR) are compared to conventional digital mammography (DM). Seventy-one patients (age range, 41 to 82 years) underwent MSR after a DM examination if questionable or suspicious breast abnormalities were not clarified by ultrasonography. The MGD and the ESAK delivered in both examinations were evaluated and compared. Two on-site radiologists rated the images in consensus according to the Breast Imaging Reporting and Data System assessment categories, which were then correlated with the final diagnoses by means of statistical generalized linear models (GLMs). Receiver operating characteristic curves were also used to assess the diagnostic performance by comparing the area under the curve (AUC). An important MGD and ESAK reduction was observed in MSR due to the monoenergetic beam. In particular, an average 43% reduction was observed for the MGD and a reduction of more than 50% for the ESAK. GLM showed higher diagnostic accuracy, especially in terms of specificity, for MSR, confirmed by AUC analysis ([Formula: see text]). The study design implied that the population was characterized by a high prevalence of disease and that the radiologists, who read the DM images before referring the patient to MSR, could have been influenced in their assessments. Within these limitations, the use of synchrotron radiation with the phase-contrast technique applied to mammography showed an important dose reduction and a higher diagnostic accuracy compared with DM. These results could further encourage research on the translation of x-ray phase-contrast imaging into the clinics.

Indexed as

breast cancerdiagnostic performancemammographymean glandular dosesynchrotron radiationx-ray phase-contrast imaging

Identifiers

PMID29430473
PMCPMC5793956
OpenAlexW2794109781

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.