Evidence map›Paper›PMID 29430443›Full record

ReviewAnnals of translational medicine2018

Electrical impedance tomography.

Beatriz Lobo, Cecilia Hermosa, Ana Abella, Federico Gordo

3 registry-linked trialsOpen access · hybridAbstract readReview
In one paragraph

Review in Annals of translational medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 29 papers.

0numbers the graph read from it
0cells of the map it votes in
29citing papers in PubMed
6.4field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04269564 nacompletednot on this mapstarted 2020, after this paper: background citation

the Use of Intraoperative Bedside Lung Ultrasound in Optimizing "Positive End Expiratory Pressure"PEEP in Patients Undergoing Laparoscopic Bariatric Surgeries

TypeinterventionalSponsorCairo UniversityRan2020 to 2020Enrolled40ConditionsAtelectasis, Postoperative PulmonaryArmsstepwise PEEP
NCT06489509 nacompletednot on this map

Distribution of Pulmonary Ventilation in Lateral Decubitus of Healthy Adults Under Non-Invasive Mechanical Ventilation Supply

TypeinterventionalSponsorAttikon HospitalRan2017 to 2018Enrolled10ConditionsNoninvasive Ventilation, Patient PositioningArmsPositive End Expiratory Pressure 5 H2O, Positive End Expiratory Pressure 10 H2O
NCT06961227 recruitingnot on this mapstarted 2025, after this paper: background citation

Comparative Analysis of Ventilation Distribution in Intensive Care: Mandatory Minute Ventilation Versus Synchronized Intermittent Mandatory Ventilation Using Electrical Impedance Tomography"

TypeobservationalSponsorHarran UniversityRan2025 to 2025Enrolled25ConditionsVentilation Modes, Mechanical Ventilation, Critical Illness, Respiratory SupportArmsNo investigational intervention
3 · Its place in the literature

Who cites it

29 citing papers in PubMed, 78 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Feasibility of electrical impedance tomography-guided PEP in children with CF and TBM.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2026
    Article
  6. Article
  7. Article
  8. Review
  9. The feasibility of using electrical impedance tomography to guide positive pressure airway clearance in children with cystic fibrosis and tracheobronchomalacia.Canadian journal of respiratory therapy : CJRT = Revue canadienne de la therapie respiratoire : RCTR · 2025
    Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Review
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Beatriz LoboIntensive Care Unit, Henares University Hospital, Coslada-Madrid, Spain.
Cecilia HermosaIntensive Care Unit, Henares University Hospital, Coslada-Madrid, Spain.
Ana AbellaIntensive Care Unit, Henares University Hospital, Coslada-Madrid, Spain.
Federico GordoIntensive Care Unit, Henares University Hospital, Coslada-Madrid, Spain.
Hospital Universitario del Henares · ESUniversidad Francisco de Vitoria · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way.

Indexed as

Acute lung injurycritical careelectric impedancephysiologic monitoringrespiratory distress syndrome

Identifiers

PMID29430443
PMCPMC5799136
OpenAlexW2781196092

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.