Evidence map›Paper›PMID 29426630›Full record

ArticleJournal of biomechanics2018

Modifying hernia mesh design to improve device mechanical performance and promote tension-free repair.

Mohamed M Ibrahim, Luke P Poveromo, Richard R Glisson, Agustin Cornejo, Alfredo E Farjat, Ken Gall, Howard Levinson

Abstract readEvaluation Study
In one paragraph

Article in Journal of biomechanics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Review
  11. Review
  12. Anti-inflammatory coating of hernia repair meshes: a 5-rabbit study.Hernia : the journal of hernias and abdominal wall surgery · 2020
    Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Mohamed M IbrahimDivision of Plastic and Reconstructive Surgery, Department of Surgery, Duke University Medical Center, Durham, NC 27710, USA.
Luke P PoveromoDuke University School of Medicine, Duke University Medical Center, Durham, NC 27710, USA.
Richard R GlissonDepartment of Orthopaedic Surgery, Duke University Medical Center, Durham, NC 27710, USA.
Agustin CornejoDivision of Plastic and Reconstructive Surgery, Department of Surgery, Duke University Medical Center, Durham, NC 27710, USA.
Alfredo E FarjatDepartment of Biostatistics and Bioinformatics, Duke University Medical Center, Durham, NC 27710, USA.
Ken GallDepartment of Mechanical Engineering and Materials Science, Duke University, Durham, NC 27710, USA.
Howard LevinsonDivision of Plastic and Reconstructive Surgery, Department of Surgery, Duke University Medical Center, Durham, NC 27710, USA; Department of Dermatology, Duke University, Durham, NC 27710, USA; Department of Pathology, Duke University, Durham, NC 27710, USA. Electronic address: howard.levinson@duke.edu.
Duke University · USDuke Medical Center · US

Funding

Duke CTSA (Composite)UL1TR001117 · NCATS · DUKE UNIVERSITY · PI BOULWARE, LEIGH E, LI, JENNIFER S · 2013 to 2017
$41.3M
A Novel Hernia Mesh to Improve Anchor Point Fixation and Prevent Hernia FormationR41GM117657 · NIGMS · DEEP BLUE MEDICAL ADVANCES, INC. · PI RUPPERT, DAVID · 2017 to 2017
$225k
NCATS NIH HHS UL1 TR001117NIGMS NIH HHS R41 GM117657
6 · The paper itself

Abstract

purposeApproximately 348,000 ventral hernia repairs are performed annually in the United States and the incisional hernia recurrence rate is approximately 20% as a result of suture and mesh device failure. Device failure is related to changes at the suture/tissue interface that leads to acute or chronic suture pull-through and surgical failure. To better manage mechanical tension, we propose a modified mesh design with extensions and demonstrate its mechanical superiority.

methodsComparative uniaxial static tensile testing was conducted on polypropylene suture and a modified mesh. Subsequently, a standard of care (SOC) mesh and modified mesh were evaluated using a tensometer in an acute hernia bench-top model.

resultsModified mesh breaking strength, extension knot breaking strength, extension disruption, and extension anchoring were superior to suture (p < .05). Modified mesh ultimate tensile strength of anchoring was superior to SOC mesh (p < .05). Various stitch patterns and modifications in device design significantly improved device tension-free performance far beyond clinically relevant benchmarks (p < .05).

conclusionsTesting demonstrates that the modified mesh outperforms SOC mesh and suture in all tested failure modes. SOC hernia mesh tears through tissue at stress levels below maximum physiologic stress, whereas, the modified hernia mesh is up to 200% stronger than SOC mesh at resisting suture tearing through tissue and maintains anchoring at stresses far beyond clinically relevant benchmarks. Modifying hernia mesh design significantly improves device mechanical performance and enhances tension-free repair.

Indexed as

Surgical MeshTensile StrengthAnimalsHernia, VentralHerniorrhaphyHumansPolypropylenesProstheses and ImplantsRecurrenceSuturesSuture TechniquesSwinePolypropylenesAnchorHerniaMeshRepairStressSutureTension

Identifiers

PMID29426630
PMCPMC5878138
OpenAlexW2790975461

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked