ArticleJournal of magnetic resonance imaging : JMRI2018
Multicenter reproducibility study of diffusion MRI and fiber tractography of the lumbosacral nerves.
Article in Journal of magnetic resonance imaging : JMRI, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Can DTI Evaluate Lumbosacral Plexus Nerve Integrity, and What can this Tell us About Lower Urinary Tract Dysfunction? A Narrative Review.Current urology reports · 2026Review
- Intra-parotid facial nerve path by MRI tractography: radio-clinical comparison in parotid tumors.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2024Observational
- Magnetic resonance neurography and diffusion tensor imaging of the sciatic nerve in hereditary transthyretin amyloidosis polyneuropathy.Journal of neurology · 2023Article
- Comparing multiband and singleband EPI in NODDI at 3 T: what are the implications for reproducibility and study sample sizes?Magma (New York, N.Y.) · 2021Article
- Article
- Peripheral Nerve Diffusion Tensor Imaging : Interreader and Test-retest Reliability as Quantified by the Standard Error of Measurement.Clinical neuroradiology · 2020Article
- A quantitative and clinical evaluation of nerve roots in lumbosacral radiculopathy using diffusion tensor imaging.Japanese journal of radiology · 2020Article
- Diffusion-weighted imaging and diffusion tensor imaging as adjuncts to conventional MRI for the diagnosis and management of peripheral nerve sheath tumors: current perspectives and future directions.European radiology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundDiffusion tensor imaging (DTI) has been applied in the lumbar and sacral nerves in vivo, but information about the reproducibility of this method is needed before DTI can be used reliably in clinical practice across centers. PURPOSE: In this multicenter study the reproducibility of DTI of the lumbosacral nerves in healthy volunteers was investigated. STUDY TYPE: Prospective control series. SUBJECTS: Twenty healthy subjects. FIELD STRENGTH/SEQUENCE: 3T MRI. 3D turbo spin echo, and 3.0 mm isotropic DTI scan. ASSESSMENT: The DTI scan was performed three times (twice in the same session, intrascan reproducibility, and once after an hour, interscan reproducibility). At site 2, 1 week later, the protocol was repeated (interweek reproducibility). Fiber tractography (FT) of the lumbar and sacral nerves (L3-S2) was performed to obtain values for fractional anisotropy, mean, axial, and radial diffusivity. STATISTICAL TESTS: Reproducibility was determined using the intraclass correlation coefficient (ICC), and power calculations were performed.
resultsFT was successful and reproducible in all datasets. ICCs for all diffusion parameters were high for intrascan (ranging from 0.70-0.85), intermediate for interscan (ranging from 0.61-0.73), and interweek reliability (ranging from 0.58-0.62). There were small but significant differences between the interweek diffusivity values (P < 0.0005). Depending on the effect size, nerve location, and parameter of interest, power calculations showed that sample sizes between 10 and 232 subjects are needed for cross-sectional studies. DATA
conclusionWe found that DTI and FT of the lumbosacral nerves have intermediate to high reproducibility within and between scans. Based on these results, 10-58 subjects are needed to find a 10% change in parameters in cross-sectional studies of the lumbar and sacral nerves. The small significant differences of the interweek comparison suggest that results from longitudinal studies need to be interpreted carefully, since small differences may also be caused by factors other than disease progression or therapeutic effects. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;48:951-963.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.