Evidence map›Paper›PMID 29423434›Full record

ArticleEndoscopy international open2018

Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions.

M H Larsen, C W Fristrup, S Detlefsen, M B Mortensen

Open access · goldAbstract read
In one paragraph

Article in Endoscopy international open, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
2.2field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 28 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Detectability and structural stability of a liquid fiducial marker in fresh ex vivo pancreas tumour resection specimens on CT and 3T MRI.Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] · 2019
    Article
  8. Review
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

M H LarsenOdense Pancreas Center (OPAC), Department of Surgery, Odense University Hospital, Odense C, Denmark.
C W FristrupOdense Pancreas Center (OPAC), Department of Surgery, Odense University Hospital, Odense C, Denmark.
S DetlefsenOdense Pancreas Center (OPAC), Department of Pathology, Odense University Hospital, Odense C, Denmark.
M B MortensenOdense Pancreas Center (OPAC), Department of Surgery, Odense University Hospital, Odense C, Denmark.
Odense University Hospital · DK

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND AND STUDY

aimDue to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions. The aim of this study was to evaluate the diagnostic accuracy. PATIENTS AND

methodsSingle-center prospective study of 41 consecutive patients referred for EUS-FNB from October 2015 to April 2016 at our center. EUS-FNB was obtained in a predefined setting regarding the procedure and pathological evaluation. Data regarding demographics, lesion, technical parameters, and diagnostic accuracy were obtained.

resultsThe study included 41 consecutive patients (22 males (54 %); median age 68 years). The average size of the lesions was 28 mm (median: 30 mm). A diagnostic specimen was identified in 40 (98 %) cases during microscopy with an average of 2.4 passes. The route was trans-duodenal in 20 cases (49 %). The histological diagnosis of the specimens was malignant in 29 cases (71 %), benign in 8 (20 %), suspicious in 2 (5 %), atypical in 1 (2 %) and in 1 (2 %) no material for microscopic evaluation was obtained. This led to a diagnostic accuracy of 93 %, sensitivity of 91 % and a specificity of 100 %. 2 cases (5 %) of self-limiting bleeding were observed. The diagnosis at follow up was malignant in 32 (78 %) of the patients.

conclusionsEUS-FNB of pancreatic mass lesions with the SharkCore needle produced specimens with a diagnostic accuracy of 93 %. The procedure was safe and easy to perform, and these data support the use of EUS-FNB in a routine setting.

Identifiers

PMID29423434
PMCPMC5803003
OpenAlexW2787454396

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked