Evidence map›Paper›PMID 29422780›Full record

ArticleIEEE sensors journal

Real-Time

Kun Ho Kim, Jeong Oen Lee, Juan Du, David Sretavan, Hyuck Choo

Abstract read
In one paragraph

Article in IEEE sensors journal. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Fourier transform infrared spectroscopy and machine learning for Porphyromonas gingivalis detection in oral bacteria.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2024
    Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kun Ho KimDepartment of Computer Science, California Institute of Technology, Pasadena, CA 91125 USA.
Jeong Oen LeeDepartment of Electrical Engineering and the Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125 USA.
Juan DuDepartment of Ophthalmology, University of California, San Francisco CA 94143 USA.
David SretavanDepartment of Ophthalmology, University of California, San Francisco CA 94143 USA.
Hyuck ChooDepartment of Electrical Engineering and the Department of Medical Engineering, California Institute of Technology, Pasadena, CA 91125 USA.

Funding

Rapid-Prototyping and Design CoreP30EY002162 · NEI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI LAKKARAJU, APARNA · 1985 to 2024
$16.8M
Intraocular Pressure Sensing Using LightR01EY024582 · NEI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI CHOO, HYUCK, SRETAVAN, DAVID W · 2016 to 2018
$989k
NEI NIH HHS R01 EY024582
6 · The paper itself

Abstract

Optimized glaucoma therapy requires frequent monitoring and timely lowering of elevated intraocular pressure (IOP). A recently developed microscale IOP-monitoring implant, when illuminated with broadband light, reflects a pressure-dependent optical spectrum that is captured and converted to measure IOP. However, its accuracy is limited by background noise and the difficulty of modeling non-linear shifts of the spectra with respect to pressure changes. Using an end-to-end calibration system to train an artificial neural network (ANN) for signal demodulation we improved the speed and accuracy of pressure measurements obtained with an optically probed IOP-monitoring implant and make it suitable for real-time in vivo IOP monitoring. The ANN converts captured optical spectra into corresponding IOP levels. We achieved an IOP-measurement accuracy of ±0.1 mmHg at a measurement rate of 100 Hz, which represents a ten-fold improvement from previously reported values. This technique allowed real-time tracking of artificially induced sub-1 s transient IOP elevations and minor fluctuations induced by the respiratory motion of the rabbits during in vivo monitoring. All in vivo sensor readings paralleled those obtained concurrently using a commercial tonometer and showed consistency within ±2 mmHg. Real-time processing is highly useful for IOP monitoring in clinical settings and home environments and improves the overall practicality of the optical IOP-monitoring approach.

Indexed as

biomedical signal processingGlaucomaimplantintraocular pressurein vivoneural networkoptical sensing

Identifiers

PMID29422780
PMCPMC5798645

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.