Micro-computed tomography for the quantification of blocked fibers in hemodialyzers.

Floris Vanommeslaeghe, Wim Van Biesen, Manuel Dierick, Matthieu Boone, Annemieke Dhondt, Sunny Eloot

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
1.8field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03820401 nacompletednot on this map

Quantification of Dialysis Performance of Different Dialyzer Membranes With Different Coagulation Strategies, Using a Reference microCT Scanning Technique

TypeinterventionalSponsorUniversity Hospital, GhentRan2018 to 2019Enrolled20ConditionsHemodialysis, CoagulationArmschoice of dialyzer, choice of dialysis mode, choice of anticoagulation strategy, preparation of dialyzer
NCT04746391 nacompletednot on this mapstarted 2021, after this paper: background citation

Assessment of a Relation Between Dialyzer Clearance and Clotting in Hemodialyzer

TypeinterventionalSponsorUniversity Hospital, GhentRan2021 to 2021Enrolled10ConditionsHemodialysis, CoagulationArmsDialyzer type, Dialysis duration
3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 20 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Observational
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Floris VanommeslaegheNephrology Department, Ghent University Hospital, Ghent, Belgium. Floris.Vanommeslaeghe@ugent.be.
Wim Van BiesenNephrology Department, Ghent University Hospital, Ghent, Belgium.
Manuel DierickUGCT, Department of Subatomic and Radiation Physics, Ghent University, Ghent, Belgium.
Matthieu BooneUGCT, Department of Subatomic and Radiation Physics, Ghent University, Ghent, Belgium.
Annemieke DhondtNephrology Department, Ghent University Hospital, Ghent, Belgium.
Sunny ElootNephrology Department, Ghent University Hospital, Ghent, Belgium.
Ghent University Hospital · BEGhent University · BE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A novel technique based on micro-CT scanning is developed to quantify coagulation in fibers of hemodialyzers. This objectivation is needed to allow accurate assessment of thrombogenicity of dialyzers used during hemodialysis, for example when comparing different strategies to avoid coagulation and/or fiber blocking. The protocol allowed imaging at a resolution of 25 µm, making it possible to count the open, non-coagulated fibers in a non-invasive way. In 3 fresh, non-used FX600 hemodialyzers, patent fiber counts were extremely consistent (10748 ± 2). To illustrate the potential of this technique, different dialysis parameters currently used as surrogates for fiber blocking were evaluated during 20 hemodialysis sessions. After dialysis, the FX600 dialyzers were visually scored for clotting, dried and subsequently weighed and scanned. The number of patent fibers (10003 [8763,10330], range 534-10692) did not correlate with any of the recorded surrogate parameters. Micro-CT scanning is a feasible, objective, non-invasive, accurate and reproducible tool for quantification of the degree of fiber blocking in a hemodialyzer after use, making it a potential gold standard for use in studies on fiber blocking during renal replacement therapies.

Indexed as

Kidneys, ArtificialBlood Coagulation FactorsEquipment DesignFiltrationHeparin, Low-Molecular-WeightHumansMembranes, ArtificialPolymersProspective StudiesRenal DialysisRenal Replacement TherapySulfonesX-Ray MicrotomographyBlood Coagulation FactorsHeparin, Low-Molecular-WeightMembranes, ArtificialPolymerspolysulfone P 1700Sulfones

Identifiers

PMID29422614
PMCPMC5805764
OpenAlexW2790326938

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.