ArticleJournal of orthopaedic surgery and research2018
Biomechanical effects of different vertebral heights after augmentation of osteoporotic vertebral compression fracture: a three-dimensional finite element analysis.
Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 47 citations in OpenAlex.
- Percutaneous Curved Vertebroplasty Decrease the Risk of Cemented Vertebra Refracture Compared with Bilateral Percutaneous Kyphoplasty in the Treatment of Osteoporotic Vertebral Compression Fractures.Clinical interventions in aging · 2024Trial
- Biomechanical study of robot-navigated targeted cross-puncture percutaneous vertebroplasty for Kümmell's disease: finite element analysis.Frontiers in rehabilitation sciences · 2026Article
- Biomechanical comparison of different bilateral percutaneous vertebroplasty in treating osteoporotic vertebral compression fractures: finite element analysis.Frontiers in surgery · 2025Article
- Clinical efficacy and biomechanical analysis of a novel hollow pedicle screw combined with kyphoplasty for the treatment of Kümmell disease.JOR spine · 2024Article
- Finite element analysis of precise puncture vertebral augmentation in the treatment of different types of osteoporotic vertebral compression fractures.BMC musculoskeletal disorders · 2024Article
- Biomechanical study between percutaneous vertebroplasty combined with cement pedicle plasty improves vertebral biomechanical stability: A finite element analysis.BMC musculoskeletal disorders · 2024Article
- Article
- Clinical Outcomes and Safety Comparison of Vertebroplasty, Balloon Kyphoplasty, and Vertebral Implant for Treatment of Vertebral Compression Fractures.AJNR. American journal of neuroradiology · 2023Article
- Biomechanical analysis of sandwich vertebrae in osteoporotic patients: finite element analysis.Frontiers in endocrinology · 2023Article
- Biomechanical evaluation of a novel anatomical plate for oblique lumbar interbody fusion compared with various fixations: a finite element analysis.Annals of translational medicine · 2022Article
- Biomechanical effects of interbody cage height on adjacent segments in patients with lumbar degeneration: a 3D finite element study.Journal of orthopaedic surgery and research · 2022Article
- Biomechanical evaluation of percutaneous cement discoplasty by finite element analysis.BMC musculoskeletal disorders · 2022Article
- Biomechanical analysis of vertebral wedge deformity in elderly women with quantitative CT-based finite element analysis.BMC musculoskeletal disorders · 2022Article
- Finite Element Analysis of a New Type of Spinal Protection Device for the Prevention and Treatment of Osteoporotic Vertebral Compression Fractures.Orthopaedic surgery · 2022Article
- Biomechanical comparison between unilateral and bilateral percutaneous vertebroplasty for osteoporotic vertebral compression fractures: A finite element analysis.Frontiers in bioengineering and biotechnology · 2022Article
- Logistic regression analysis on risk factors of augmented vertebra recompression after percutaneous vertebral augmentation.Journal of orthopaedic surgery and research · 2021Article
- A Multiscale Finite Element Analysis of Balloon Kyphoplasty to Investigate the Risk of Bone-Cement Separation In Vivo.International journal of spine surgery · 2021Article
- Finite element analysis of wedge and biconcave deformity in four different height restoration after augmentation of osteoporotic vertebral compression fractures.Journal of orthopaedic surgery and research · 2021Article
- Midterm outcome after posterior stabilization of unstable Midthoracic spine fractures in the elderly.BMC musculoskeletal disorders · 2021Article
- Effect of multi-platform extended care on postoperative self-efficacy and quality of life in patients with osteoporotic vertebral compressive fracture.American journal of translational research · 2021Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
backgroundClinical results have shown that different vertebral heights have been restored post-augmentation of osteoporotic vertebral compression fractures (OVCFs) and the treatment results are consistent. However, no significant results regarding biomechanical effects post-augmentation have been found with different types of vertebral deformity or vertebral heights by biomechanical analysis. Therefore, the present study aimed to investigate the biomechanical effects between different vertebral heights of OVCFs before and after augmentation using three-dimensional finite element analysis.
methodsFour patients with OVCFs of T12 underwent computed tomography (CT) of the T11-L1 levels. The CT images were reconstructed as simulated three-dimensional finite-element models of the T11-L1 levels (before and after the T12 vertebra was augmented with cement). Four different kinds of vertebral height models included Genant semi-quantitative grades 0, 1, 2, and 3, which simulated unilateral augmentation. These models were assumed to represent vertical compression and flexion, left flexion, and right flexion loads, and the von Mises stresses of the T12 vertebral body were assessed under different vertebral heights before and after bone cement augmentation.
resultsData showed that the von Mises stresses significantly increased under four loads of OVCFs of the T12 vertebral body before the operation from grade 0 to grade 3 vertebral heights. The maximum stress of grade 3 vertebral height pre-augmentation was produced at approximately 200%, and at more than 200% for grade 0. The von Mises stresses were significantly different between different vertebral heights preoperatively. The von Mises stresses of the T12 vertebral body significantly decreased in four different loads and at different vertebral body heights (grades 0-3) after augmentation. There was no significant difference between the von Mises stresses of grade 0, 1, and 3 vertebral heights postoperatively. The von Mises stress significantly decreased between pre-augmentation and post-augmentation in T12 OVCF models of grade 0-3 vertebral heights.
conclusionVertebral augmentation can sufficiently reduce von Mises stresses at different heights of OVCFs of the vertebral body, although this technique does not completely restore vertebral height to the anatomical criteria.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.