ArticleJournal of structural biology2018
Comparison of 3D cellular imaging techniques based on scanned electron probes: Serial block face SEM vs. Axial bright-field STEM tomography.
Article in Journal of structural biology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 15 citations in OpenAlex.
- The MICOS Complex Regulates Mitochondrial Structure and Oxidative Stress During Age-Dependent Structural Deficits in the Kidney.bioRxiv : the preprint server for biology · 2026Article
- Application of STEM tomography to investigate smooth ER morphology under stress conditions.Journal of microscopy · 2025Article
- Platelet-Rich Plasma in Dermatology: New Insights on the Cellular Mechanism of Skin Repair and Regeneration.Life (Basel, Switzerland) · 2023Review
- Serial Block Face-Scanning Electron Microscopy as a Burgeoning Technology.Advanced biology · 2023Review
- Estimating the glutamate transporter surface density in distinct sub-cellular compartments of mouse hippocampal astrocytes.PLoS computational biology · 2022Article
- Structural analysis of resting mouse platelets by 3D-EM reveals an unexpected variation in α-granule shape.Platelets · 2021Article
- Canalicular system reorganization during mouse platelet activation as revealed by 3D ultrastructural analysis.Platelets · 2021Article
- Determination of secretory granule maturation times in pancreatic islet β-cells by serial block-face electron microscopy.Journal of structural biology · 2020Article
- Quantitative method for estimating stain density in electron microscopy of conventionally prepared biological specimens.Journal of microscopy · 2020Article
- 3D ultrastructural analysis of α-granule, dense granule, mitochondria, and canalicular system arrangement in resting human platelets.Research and practice in thrombosis and haemostasis · 2020Article
- STEM tomography of high-pressure frozen and freeze-substituted cells: a comparison of image stacks obtained at 200 kV or 300 kV.Histochemistry and cell biology · 2018Article
- Electron tomography-a tool for ultrastructural 3D visualization in cell biology and histology.Wiener medizinische Wochenschrift (1946) · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
13 authors at 3 institutions in 2 countries.
Funding
Abstract
Microscopies based on focused electron probes allow the cell biologist to image the 3D ultrastructure of eukaryotic cells and tissues extending over large volumes, thus providing new insight into the relationship between cellular architecture and function of organelles. Here we compare two such techniques: electron tomography in conjunction with axial bright-field scanning transmission electron microscopy (BF-STEM), and serial block face scanning electron microscopy (SBF-SEM). The advantages and limitations of each technique are illustrated by their application to determining the 3D ultrastructure of human blood platelets, by considering specimen geometry, specimen preparation, beam damage and image processing methods. Many features of the complex membranes composing the platelet organelles can be determined from both approaches, although STEM tomography offers a higher ∼3 nm isotropic pixel size, compared with ∼5 nm for SBF-SEM in the plane of the block face and ∼30 nm in the perpendicular direction. In this regard, we demonstrate that STEM tomography is advantageous for visualizing the platelet canalicular system, which consists of an interconnected network of narrow (∼50-100 nm) membranous cisternae. In contrast, SBF-SEM enables visualization of complete platelets, each of which extends ∼2 µm in minimum dimension, whereas BF-STEM tomography can typically only visualize approximately half of the platelet volume due to a rapid non-linear loss of signal in specimens of thickness greater than ∼1.5 µm. We also show that the limitations of each approach can be ameliorated by combining 3D and 2D measurements using a stereological approach.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.