Evidence map›Paper›PMID 29404891›Full record

Observational studyJournal of clinical monitoring and computing2018

Assessment of changes in blood glucose concentration with intravascular microdialysis.

Marc-Olivier Fischer, Corentin Gouëzel, Sabine Fradin, Vladimir Saplacan, Jean-Louis Gérard, Jean-Luc Fellahi, Jean-Luc Hanouz

Abstract readObservational Study
PubMed Publisher
In one paragraph

Observational study in Journal of clinical monitoring and computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.2field-weighted citation impact, top 47% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Marc-Olivier FischerPôle Réanimations Anesthésie SAMU/SMUR, Department of Anaesthesia and Intensive Care Medicine, Caen University Hospital de Caen, Avenue de la Côte de Nacre, CS 30001, 14000, Caen, France. fischer-mo@chu-caen.fr.
Corentin GouëzelPôle Réanimations Anesthésie SAMU/SMUR, Department of Anaesthesia and Intensive Care Medicine, Caen University Hospital de Caen, Avenue de la Côte de Nacre, CS 30001, 14000, Caen, France.
Sabine FradinDepartment of Biology, University Hospital of Caen, Avenue de la Côte de Nacre, CS 30001, 14000, Caen, France.
Vladimir SaplacanCardiac Surgery, University Hospital of Caen, Avenue de la Côte de Nacre, CS 30001, 14000, Caen, France.
Jean-Louis GérardPôle Réanimations Anesthésie SAMU/SMUR, Department of Anaesthesia and Intensive Care Medicine, Caen University Hospital de Caen, Avenue de la Côte de Nacre, CS 30001, 14000, Caen, France.
Jean-Luc FellahiDepartment of Anaesthesia and Intensive Care Medicine, Hôpital cardiologique Louis Pradel, Avenue du Doyen Lepine, 69 677, Lyon, France.
Jean-Luc HanouzPôle Réanimations Anesthésie SAMU/SMUR, Department of Anaesthesia and Intensive Care Medicine, Caen University Hospital de Caen, Avenue de la Côte de Nacre, CS 30001, 14000, Caen, France.
Université de Caen Normandie · FRHôpital Louis Pradel · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Blood glucose and its variability of is a major prognostic factor associated with morbidity. We hypothesized that intravenous microdialysis incorporated in a central venous catheter (CVC) would be interchangeable with changes in blood glucose measured by the reference method using a blood gas analyzer. Microdialysis and central venous blood glucose measurements were simultaneously recorded in high-risk cardiac surgical patients. The correlation between absolute values was determined by linear regression and the Bland-Altman test for repeated measurements was used to compare bias, precision, and limits of agreement. Changes in blood glucose measurement were evaluated by four-quadrant plot and trend interchangeability methods (TIM). In the 23 patients analyzed, the CVC was used as part of standard care with no complications. The correlation coefficient for absolute values (N = 99) was R = 0.91 (P < 0.001). The bias, precision and limits of agreement were - 9.1, 17.4 and - 43.2 to 24.9 mg/dL, respectively. The concordance rate for changes in blood glucose measurements (N = 77) was 85% with the four-quadrant plot. The TIM showed that 14 (18%) changes of blood glucose measurements were uninterpretable. Among the remaining 63 (82%) interpretable changes, 23 (37%) were interchangeable, 13 (20%) were in the gray zone, and 27 (43%) were not interchangeable. Microdialysis using a CVC appears to provide imprecise absolute blood glucose values with risk of insulin misuse. Moreover, only one third of changes in blood glucose measurements were interchangeable with the reference method using the TIM.

Indexed as

AgedBlood Chemical AnalysisBlood GlucoseCardiac Surgical ProceduresCatheterization, Central VenousCentral Venous CathetersCohort StudiesFemaleHumansMaleMicrodialysisMiddle AgedMonitoring, IntraoperativeProspective StudiesBlood GlucoseBlood glucoseCardiac surgeryMicrodialysisMonitoringTrends

Identifiers

PMID29404891
OpenAlexW2791649070

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.