Evidence map›Paper›PMID 29403158›Full record

ArticleJournal of process control2017

Hybrid online sensor error detection and functional redundancy for systems with time-varying parameters.

Jianyuan Feng, Kamuran Turksoy, Sediqeh Samadi, Iman Hajizadeh, Elizabeth Littlejohn, Ali Cinar

Abstract read
In one paragraph

Article in Journal of process control, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Metabolic Models, in Silico Trials, and Algorithms.Diabetes technology & therapeutics · 2025
    Review
  2. Metabolic Models, in Silico Trials, and Algorithms.Journal of diabetes science and technology · 2025
    Review
  3. Article
  4. Recent advances in the precision control strategy of artificial pancreas.Medical & biological engineering & computing · 2024
    Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jianyuan FengDepartment of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, United States.
Kamuran TurksoyDepartment of Biomedical Engineering, Illinois Institute of Technology, Chicago, IL, United States.
Sediqeh SamadiDepartment of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, United States.
Iman HajizadehDepartment of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, United States.
Elizabeth LittlejohnBiological Sciences Division, University of Chicago, Chicago, IL 60637, United States.
Ali CinarDepartment of Chemical and Biological Engineering, Illinois Institute of Technology, Chicago, IL, United States.

Funding

Control Systems for Artificial Pancreas Use During and After ExerciseDP3DK101075 · NIDDK · ILLINOIS INSTITUTE OF TECHNOLOGY · PI CINAR, ALI · 2013 to 2013
$2.5M
Fault-tolerant Control Systems for Artificial PancreasDP3DK101077 · NIDDK · ILLINOIS INSTITUTE OF TECHNOLOGY · PI CINAR, ALI · 2013 to 2013
$2.0M
NIDDK NIH HHS DP3 DK101075NIDDK NIH HHS DP3 DK101077
6 · The paper itself

Abstract

Supervision and control systems rely on signals from sensors to receive information to monitor the operation of a system and adjust manipulated variables to achieve the control objective. However, sensor performance is often limited by their working conditions and sensors may also be subjected to interference by other devices. Many different types of sensor errors such as outliers, missing values, drifts and corruption with noise may occur during process operation. A hybrid online sensor error detection and functional redundancy system is developed to detect errors in online signals, and replace erroneous or missing values detected with model-based estimates. The proposed hybrid system relies on two techniques, an outlier-robust Kalman filter (ORKF) and a locally-weighted partial least squares (LW-PLS) regression model, which leverage the advantages of automatic measurement error elimination with ORKF and data-driven prediction with LW-PLS. The system includes a nominal angle analysis (NAA) method to distinguish between signal faults and large changes in sensor values caused by real dynamic changes in process operation. The performance of the system is illustrated with clinical data continuous glucose monitoring (CGM) sensors from people with type 1 diabetes. More than 50,000 CGM sensor errors were added to original CGM signals from 25 clinical experiments, then the performance of error detection and functional redundancy algorithms were analyzed. The results indicate that the proposed system can successfully detect most of the erroneous signals and substitute them with reasonable estimated values computed by functional redundancy system.

Indexed as

CGMFunctional sensor redundancyGlucose concentrationsKalman filterLocally weighted partial least squares regressionSensor error detection

Identifiers

PMID29403158
PMCPMC5796791

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.