ArticleJournal of process control2017
Hybrid online sensor error detection and functional redundancy for systems with time-varying parameters.
Article in Journal of process control, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Metabolic Models, in Silico Trials, and Algorithms.Diabetes technology & therapeutics · 2025Review
- Metabolic Models, in Silico Trials, and Algorithms.Journal of diabetes science and technology · 2025Review
- Cyber-Physical-Human Systems in Precision Medicine: Advances in Artificial Pancreas for Treatment of Diabetes.Annual reviews in control · 2025Article
- Recent advances in the precision control strategy of artificial pancreas.Medical & biological engineering & computing · 2024Review
- Multi-Model Sensor Fault Detection and Data Reconciliation: A Case Study with Glucose Concentration Sensors for Diabetes.AIChE journal. American Institute of Chemical Engineers · 2019Article
- Incorporating Unannounced Meals and Exercise in Adaptive Learning of Personalized Models for Multivariable Artificial Pancreas Systems.Journal of diabetes science and technology · 2018Article
- Multi-level Supervision and Modification of Artificial Pancreas Control System.Computers & chemical engineering · 2018Article
- Hybrid online sensor error detection and functional redundancy for systems with time-varying parameters.Journal of process control · 2017Article
- Multivariable Adaptive Artificial Pancreas System in Type 1 Diabetes.Current diabetes reports · 2017Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Supervision and control systems rely on signals from sensors to receive information to monitor the operation of a system and adjust manipulated variables to achieve the control objective. However, sensor performance is often limited by their working conditions and sensors may also be subjected to interference by other devices. Many different types of sensor errors such as outliers, missing values, drifts and corruption with noise may occur during process operation. A hybrid online sensor error detection and functional redundancy system is developed to detect errors in online signals, and replace erroneous or missing values detected with model-based estimates. The proposed hybrid system relies on two techniques, an outlier-robust Kalman filter (ORKF) and a locally-weighted partial least squares (LW-PLS) regression model, which leverage the advantages of automatic measurement error elimination with ORKF and data-driven prediction with LW-PLS. The system includes a nominal angle analysis (NAA) method to distinguish between signal faults and large changes in sensor values caused by real dynamic changes in process operation. The performance of the system is illustrated with clinical data continuous glucose monitoring (CGM) sensors from people with type 1 diabetes. More than 50,000 CGM sensor errors were added to original CGM signals from 25 clinical experiments, then the performance of error detection and functional redundancy algorithms were analyzed. The results indicate that the proposed system can successfully detect most of the erroneous signals and substitute them with reasonable estimated values computed by functional redundancy system.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.