Evidence map›Paper›PMID 29398989›Full record

ArticleHSS journal : the musculoskeletal journal of Hospital for Special Surgery2018

The Primary Stability of a Bioabsorbable Poly-L-Lactic Acid Suture Anchor for Rotator Cuff Repair Is Not Improved with Polymethylmethacrylate or Bioabsorbable Bone Cement Augmentation.

Mehmet F Güleçyüz, Michael Kraus-Petersen, Christian Schröder, Andreas Ficklscherer, Markus U Wagenhäuser, Christian Braun, Peter E Müller, Matthias F Pietschmann

Open access · bronzeAbstract read
In one paragraph

Article in HSS journal : the musculoskeletal journal of Hospital for Special Surgery, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 77% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Mehmet F GüleçyüzDepartment of Orthopaedics, Physical Medicine and Rehabilitation, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany.
Michael Kraus-Petersen2Laboratory for Biomechanics and Experimental Orthopedics, University of Munich (Ludwig-Maximilian-University), Feodor-Lynen-Strasse 19, 81377 Munich, Germany.
Christian Schröder2Laboratory for Biomechanics and Experimental Orthopedics, University of Munich (Ludwig-Maximilian-University), Feodor-Lynen-Strasse 19, 81377 Munich, Germany.
Andreas FicklschererOrthopädie Oberland, Alpenstraße 7, 82362 Weilheim in Oberbayern, Germany.
Markus U Wagenhäuser4Department of Vascular and Endovascular Surgery, University Hospital Düsseldorf, Moorenstrasse 5, 40225 Düsseldorf, Germany.
Christian Braun5Institute of Forensic Medicine, University of Munich (Ludwig-Maximilian-University), Nußbaumstraße 26, 80336 Munich, Germany.
Peter E MüllerDepartment of Orthopaedics, Physical Medicine and Rehabilitation, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany.
Matthias F PietschmannDepartment of Orthopaedics, Physical Medicine and Rehabilitation, University Hospital, LMU Munich, Marchioninistrasse 15, 81377 Munich, Germany.
Ludwig-Maximilians-Universität München · DEDüsseldorf University Hospital · DEKliniken des Bezirks Oberbayern · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe incidence of osteoporosis and rotator cuff tears increases with age. Cement augmentation of bones is an established method in orthopedic and trauma surgery. QUESTIONS/PURPOSES: This study analyses if polymethylmethacrylate or bioabsorbable cement can improve the primary stability of a bioabsorbable suture anchor in vitro in comparison to a non-augmented suture anchor in osteoporotic human humeri.

methodsThe trabecular bone mineral density was measured to ensure osteopenic human specimens. Then the poly-l-lactic acid Bio-Corkscrew® FT was implanted in the greater tuberosity footprint with polymethylmethacrylate Refobacin® cement augmentation (

resultsThe Cerament™ augmented Bio-Corkscrew® FT yielded the highest failure loads (206.7 N), followed by polymethylmethacrylate Refobacin® augmentation (206.1 N) and without augmentation (160.0 N). The system displacement was lowest for Cerament™ augmentation (0.72 mm), followed by polymethylmethacrylate (0.82 mm) and without augmentation (1.50 mm). Statistical analysis showed no significant differences regarding the maximum failure loads (

conclusionThe primary stability of the Bio-Corkscrew® FT is not influenced by bone cement augmentation with polymethylmethacrylate Refobacin® or with bioabsorbable Cerament™ in comparison to the non-cemented anchors. The cement augmentation of rotator cuff suture anchors in osteoporotic bones remains questionable since biomechanical tests show no significant advantage.

Indexed as

augmentationbiomechanicsbone cementbone mineral densityosteoporosispoly-l-lactic acid suture anchorrotator cuff

Identifiers

PMID29398989
PMCPMC5786586
OpenAlexW2765594200

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.