ArticleBiomedical engineering online2018

Windkessel model of hemodynamic state supported by a pulsatile ventricular assist device in premature ventricle contraction.

Keun Her, Joon Yeong Kim, Ki Moo Lim, Seong Wook Choi

Open access · goldAbstract read
In one paragraph

Article in Biomedical engineering online, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Keun HerDepartment of Cardiovascular and Thoracic Surgery, Soonchunhyang University Hospital, Bucheon-si, Republic of Korea.
Joon Yeong KimProgram of Mechanical and Biomedical Engineering, College of Engineering, Kangwon National University, Chuncheon-si, Republic of Korea.
Ki Moo LimDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi, Republic of Korea.
Seong Wook ChoiProgram of Mechanical and Biomedical Engineering, College of Engineering, Kangwon National University, Chuncheon-si, Republic of Korea. swchoe@kangwon.ac.kr.ORCID http://orcid.org/0000-0003-4045-4384
Kangwon National University · KRKumoh National Institute of Technology · KRSoonchunhyang University Hospital Seoul · KR

Funding

Ministry of Trade, Industry and Energy (KR) R0004491National Research Foundation of Korea (KR) C1013660-01-01
6 · The paper itself

Abstract

backgroundCounter-pulsation control (CPC) by ventricular assist devices (VADs) is believed to reduce cardiac load and increase coronary perfusion. However, patients with VADs have a higher risk of arrhythmia, which may cause the CPC to fail. Consequently, CPC has not been applied by VADs in clinical practice. The phase-locked loop (PLL) algorithm for CPC is readily implemented in VADs; however, it requires a normal, consistent heartbeat for adequate performance. When an arrhythmia occurs, the algorithm maintains a constant pumping rate despite the unstable heartbeat. Therefore, to apply the PLL algorithm to CPC, the hemodynamic effects of abnormal heartbeats must be analyzed.

objectivesThis study sought to predict the hemodynamic effects in patients undergoing CPC using VADs, based on electrocardiogram (ECG) data, including a wide range of heart rate (HR) changes caused by premature ventricular contraction (PVC) or other reasons.

methodsA four-element Windkessel hemodynamic model was used to reproduce the patient's aortic blood pressure in this study. ECG data from 15 patients with severe congestive heart failure were used to assess the effect of the CPC on the patients' hemodynamic state. The input and output flow characteristics of the pulsatile VAD (LibraHeart I, Cervika, Korea) were measured using an ultrasound blood flow meter (TS410, Transonic, USA), with the aortic pressure maintained at 80-120 mmHg. All other patient conditions were also reproduced.

resultsIn patients with PVCs or normal heartbeats, CPC controlled by a VAD reduced the cardiac load by 20 and 40%, respectively. When the HR was greater for other reasons, such as sinus tachycardia, simultaneous ejection from the heart and VAD was observed; however, the cardiac load was not increased by rapid cardiac contractions resulting from decreased left ventricle volume. These data suggest that the PLL algorithm reduces the cardiac load and maintains consistent hemodynamic changes.

Indexed as

Heart-Assist DevicesPulsatile FlowAdultAgedAlgorithmsArrhythmias, CardiacBlood PressureComputer SimulationElectrocardiographyFemaleHeart FailureHeart RateHeart VentriclesHemodynamicsHumansMaleArrhythmiaCounter-pulsation controlPhase-locked loopPulsatile ventricular assist deviceWindkessel model

Identifiers

PMID29394944
PMCPMC5797383
OpenAlexW2796488999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.