ArticleJAMA ophthalmology2018
Ultrasonography Assessments of Optic Nerve Sheath Diameter as a Noninvasive and Dynamic Method of Detecting Changes in Intracranial Pressure.
Article in JAMA ophthalmology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 3 registered trials, which are not on this map. Cited by 71 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Sonography of the Optic Nerve Sheath Diameter for Detection of Elevated Intracranial Pressure Compared to Computed Tomography
The Effect of End-tidal Carbon Dioxide Level on the Optic Nerve Sheath Diameter Measured by a Transorbital Ultrasonography in Pediatric Patients
Ultrasonography of Optic Nerve Sheath Diameter for Noninvasive Detection of Raised Intracranial Pressure: a Chinese Multicenter Study
Who cites it
71 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Optic nerve sheath diameter measured sonographically as non-invasive estimator of intracranial pressure: a systematic review and meta-analysis.Intensive care medicine · 2018Pooled it
- Intraindividual Optic Nerve Sheath Variation and Intracranial Pressure Changes: A Systematic Review and Meta-Analysis.Journal of neuroimaging : official journal of the American Society of NeuroimagingPooled it
- Norepinephrine versus colloid for preventing spinal anesthesia-induced hypotension and its impact on intracranial pressure in preeclamptic parturients: a randomized double-blind controlled trial.BMC pregnancy and childbirth · 2026Trial
- Monitoring of optic sheath diameter during acute migraine attack: an objective criteria for the severity of disease.Acta neurologica Belgica · 2024Trial
- Evaluation of CSF pressures, OCT parameters, and transorbital ultrasonographic measurements in ıdiopathic ıntracranial hypertension.International ophthalmology · 2026Article
- 3D Freehand Ultrasound Imaging of Optic Nerve Sheath.Investigative radiology · 2026Article
- Ultrasonographic optic nerve sheath diameter for predicting elevated intracranial pressure and clinical severity in children: a prospective observational study.European journal of pediatrics · 2026Observational
- Potential role of standardized orbital ultrasound in the management of spontaneous CSF leaks.Neurosurgical review · 2026Article
- Cerebrospinal fluid opening pressure in relation to symptomatology and craniocervical anatomy in patients with myalgic encephalomyelitis/chronic fatigue syndrome.Frontiers in medicine · 2026Article
- Systematic review of the diagnostic accuracy of noninvasive intracranial pressure monitoring using optic nerve sheath diameter and the Brain4Care system.Brain & spine · 2026Review
- Derivative indices of optic nerve sheath diameter: a novel ultrasound-based approach for non-invasive intracranial pressure monitoring in neurocritical patients.Frontiers in neurology · 2026Article
- Automated Semisupervised Measurement of Optic Nerve Sheath Diameter From CT Following Traumatic Brain Injury.International journal of biomedical imaging · 2026Article
- The challenge of diagnosing intracranial pressure elevations as an otolaryngologist.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2025Review
- Point of care ultrasound assessment of the optic nerve sheath diameter in critically ill children.BMC pediatrics · 2025Observational
- Learning and reproducibility of ultrasonographic assessment of the optic nerve sheath diameter: A cohort study.European journal of anaesthesiology and intensive care · 2025Article
- Ultrasonic optic nerve sheath diameter as a new predictor for the mortality of patients with large hemispheric infarction.Scientific reports · 2025Article
- Deep learning based optic nerve sheath diameter characterization and structure quantification on transorbital ultrasound images.Frontiers in medicine · 2025Article
- Objective test findings in patients with chronic eye symptoms seeking care at an outpatient neck center: ligamentous cervical instability etiology?Frontiers in neurology · 2025Article
- Idiopathic intracranial hypertension: Imaging and clinical fundamentals.World journal of radiology · 2024Review
- Optic nerve sheath measurement to monitor disease activity in giant cell arteritis: a pilot study.Clinical rheumatology · 2024Article
11 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Importance: The crtierion standard method for monitoring intracranial pressure (ICP) can result in complications and pain. Hence, noninvasive, repeatable methods would be valuable. Objective: To examine how ultrasonographic optic nerve sheath diameter (ONSD) correlated with noninvasive and dynamically monitored ICP changes. Design, Setting, and Participants: The ONSD was measured before the lumbar puncture (LP) in 60 patients on admission. Patients with elevated ICP were divided into group 1 (200 < LP ≤ 300 mm H2O) and group 2 (LP > 300 mm H2O). Patients underwent follow-up ONSD and LP measurements within 1 month. We analyzed the correlations between the ONSD and ICP on admission and between the changes in ONSD and ICP, which were the respective changes in ONSD and ICP from admission to follow-up. Main Outcomes and Measures: The ultrasonographic ONSD and ICP were measured on admission and follow-up. The correlations between the ONSD and ICP on admission and between the changes in ONSD and ICP were analyzed using Pearson correlation analyses. Results: For 60 patients (Han nationality; mean [SD] age, 36.2 [12.04] years; 29 [48%] female) on admission, the ONSD and ICP values were strongly correlated, with an r of 0.798 (95% CI, 0.709-0.867; P < .001). Twenty-five patients with elevated ICP who completed the follow-up were included. The mean (SD) ONSD and ICP on admission were 4.50 (0.54) mm and 302.40 (54.26) mm H2O, respectively. The ONSD and ICP values obtained on admission were strongly correlated , with an r of 0.724 (95% CI, 0.470-0.876; P < .001). The mean (SD, range) changes in ICP and ONSD were 126.64 (52.51 mm H2O, 20-210 mm H2O) (95% CI, 106.24-146.07) and 1.00 (0.512 mm, 0.418-2.37 mm) (95% CI, 0.83-1.20), respectively. The change in ONSD was strongly correlated with the change in ICP, with an r of 0.702 (95% CI, 0.425-0.870; P < .001). The follow-up evaluations revealed that the elevated ICP and dilated ONSD had returned to normal, and no evidence of difference was found in the mean ONSDs between group 1 (3.49 mm; 95% CI, 3.34-3.62 mm) and group 2 (3.51 mm; 95% CI, 3.44-3.59 mm) (P = .778) at follow-up. Conclusions and Relevance: The dilated ONSDs decreased along with the elevated ICP reduction. Ultrasonographic ONSD measurements may be a useful, noninvasive tool for dynamically evaluating ICP.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.