Evidence map›Paper›PMID 29390005›Full record

ArticlePloS one2018

Design and construction of an optimized transmit/receive hybrid birdcage resonator to improve full body images of medium-sized animals in 7T scanner.

Nibardo Lopez Rios, Philippe Pouliot, Konstantinos Papoutsis, Alexandru Foias, Nikola Stikov, Frédéric Lesage, Mathieu Dehaes, Julien Cohen-Adad

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.1field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Hardware Considerations for Preclinical Magnetic Resonance of the Kidney.Methods in molecular biology (Clifton, N.J.) · 2021
    Article
  3. Review
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 5 institutions in 3 countries.

Nibardo Lopez RiosDepartment of Electrical Engineering, Ecole Polytechnique Montreal, Montreal, QC, Canada.ORCID 0000-0002-4791-8260
Philippe PouliotDepartment of Electrical Engineering, Ecole Polytechnique Montreal, Montreal, QC, Canada.
Konstantinos PapoutsisDepartment of Electrical Engineering, Ecole Polytechnique Montreal, Montreal, QC, Canada.
Alexandru FoiasDepartment of Electrical Engineering, Ecole Polytechnique Montreal, Montreal, QC, Canada.
Nikola StikovDepartment of Electrical Engineering, Ecole Polytechnique Montreal, Montreal, QC, Canada.
Frédéric LesageDepartment of Electrical Engineering, Ecole Polytechnique Montreal, Montreal, QC, Canada.
Mathieu DehaesSainte-Justine Hospital University Center, Montreal, Canada.
Julien Cohen-AdadDepartment of Electrical Engineering, Ecole Polytechnique Montreal, Montreal, QC, Canada.
Montreal Heart Institute · CAPolytechnique Montréal · CACentre Hospitalier Universitaire Sainte-Justine · CAUniversidad de Oriente · CUUniversity of Oxford · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The purpose of this work was to develop an optimized transmit/receive birdcage coil to extend the possibilities of a 7T preclinical MRI system to conduct improved full body imaging in medium-sized animals, such as large New Zealand rabbits. The coil was designed by combining calculation and electromagnetic simulation tools. The construction was based on precise mechanical design and careful building practice. A 16-leg, 20 cm long, 16 cm inner diameter, shielded quadrature hybrid structure was selected. Coil parameters were assessed on the bench and images were acquired on phantoms and rabbits. The results were compared to simulations and data obtained with an available commercial coil. An inexpensive assembly with an increase of 2 cm in useful inner diameter and 50 Ω matching with larger animals was achieved. A reduction in radiofrequency (RF) power demand of 31.8%, an improvement in image uniformity of 18.5 percentage points and an increase in signal-to-noise ratio of up to 42.2% were revealed by phantom image acquisitions, which was confirmed by in vivo studies. In conclusion, the proposed coil extended the possibilities of a preclinical 7T system as it improved image studies in relatively large animals by reducing the RF power demand, and increasing image uniformity and signal-to-noise ratio. Shorter scans and time under anesthesia or reduced RF exposure, resulting in better images and lower animal health risk during in vivo experiments, were achieved.

Indexed as

Equipment DesignAnimalsMagnetic Resonance ImagingPhantoms, ImagingRabbits

Identifiers

PMID29390005
PMCPMC5794134
OpenAlexW2789338184

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked