MR-based motion correction for cardiac PET parametric imaging: a simulation study.

Rong Guo, Yoann Petibon, Yixin Ma, Georges El Fakhri, Kui Ying, Jinsong Ouyang

Abstract read
In one paragraph

Article in EJNMMI physics, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Rong GuoDepartment of Engineering Physics, Tsinghua University, Beijing, 10084, China.
Yoann PetibonGordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, 02114, USA.
Yixin MaDepartment of Engineering Physics, Tsinghua University, Beijing, 10084, China.
Georges El FakhriGordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, 02114, USA.
Kui YingDepartment of Engineering Physics, Tsinghua University, Beijing, 10084, China.
Jinsong OuyangGordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, MA, 02114, USA. ouyang.jinsong@mgh.harvard.edu.ORCID http://orcid.org/0000-0003-4245-170X

Funding

Unified Joint Statistical Reconstruction of PET & MRP41EB022544 · NIBIB · YALE UNIVERSITY · PI Kira Grogg · 2017 to 2026
$14.8M
PET/MR Mapping of Myocardial Membrane PotentialR01HL137230 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI EL FAKHRI, GEORGES · 2017 to 2020
$3.3M
Quantitative Simultaneous Cardiac PET-MRR01HL118261 · NHLBI · MASSACHUSETTS GENERAL HOSPITAL · PI OUYANG, JINSONG · 2014 to 2018
$2.6M
National Heart, Lung, and Blood Institute R01-HL118261National Institute of Biomedical Imaging and Bioengineering P41-EB022544NHLBI NIH HHS R01 HL118261NHLBI NIH HHS R01 HL137230NIBIB NIH HHS P41 EB022544
6 · The paper itself

Abstract

backgroundBoth cardiac and respiratory motions bias the kinetic parameters measured by dynamic PET. The aim of this study was to perform a realistic positron emission tomography-magnetic resonance (PET-MR) simulation study using 4D XCAT to evaluate the impact of MR-based motion correction on the estimation of PET myocardial kinetic parameters using PET-MR. Dynamic activity distributions were obtained based on a one-tissue compartment model with realistic kinetic parameters and an arterial input function. Realistic proton density/T1/T2 values were also defined for the MRI simulation. Two types of motion patterns, cardiac motion only (CM) and both cardiac and respiratory motions (CRM), were generated. PET sinograms were obtained by the projection of the activity distributions. PET image for each time frame was obtained using static (ST), gated (GA), non-motion-corrected (NMC), and motion-corrected (MC) methods. Voxel-wise unweighted least squares fitting of the dynamic PET data was then performed to obtain K

resultsBoth cardiac and respiratory motions introduce blurring in the PET parametric images if the motion is not corrected. Conventional cardiac gating is limited by high noise level on parametric images. Dual cardiac and respiratory gating further increases the noise level. In contrast to GA, the MR-based MC method reduces motion blurring in parametric images without increasing noise level. It also improves the myocardial defect delineation as compared to NMC method. Finally, the MR-based MC method yields lower bias and variance in K

conclusionsThis simulation study suggests that the MR-based motion-correction method using PET-MR greatly reduces motion blurring on parametric images and yields less K

Indexed as

Cardiac PET parametric imagingMR-based PET motion correctionMyocardial perfusionPET-MR

Identifiers

PMID29388075
PMCPMC5792384

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.