ArticleDer Orthopade2018
Accurate placement of cervical pedicle screws using 3D-printed navigational templates : An improved technique with continuous image registration.
Article in Der Orthopade, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Patient-specific drill template for C2 transoral pedicle insertion in complete reduction of atlantoaxial dislocation: cadaveric efficacy and accuracy assessments.Journal of orthopaedic surgery and research · 2019Trial
- A new individually designed 3D printing guide plate-assisted internal fixator (INFIX) surgery for the treatment of pelvic fractures.Journal of orthopaedic surgery and research · 2025Review
- The Accuracy of Patient-Specific Spinal Drill Guides Is Non-Inferior to Computer-Assisted Surgery: The Results of a Split-Spine Randomized Controlled Trial.Journal of personalized medicine · 2022Article
- Template guided cervical pedicle screw instrumentation.North American Spine Society journal · 2022Article
- Clinical applications and prospects of 3D printing guide templates in orthopaedics.Journal of orthopaedic translation · 2022Review
- A semi-automatic seed point-based method for separation of individual vertebrae in 3D surface meshes: a proof of principle study.International journal of computer assisted radiology and surgery · 2021Article
- Design of custom-made navigational template of femoral head and pilot research in total hip resurfacing arthroplasty.BMC surgery · 2020Article
- Anatomic techniques for cervical pedicle screw placement.Journal of spine surgery (Hong Kong) · 2020Review
- A Comparative Study of C2 Pedicle or Pars Screw Placement with Assistance from a 3-Dimensional (3D)-Printed Navigation Template versus C-Arm Based Navigation.Medical science monitor : international medical journal of experimental and clinical research · 2019Article
- Repair of osteonecrosis of the femoral head : 3D printed Cervi cornus Colla deproteinized bone scaffolds.Der Orthopade · 2019Article
- [Digitalization and artificial intelligence in orthopedics and traumatology].Der Orthopade · 2018Article
- 3-dimensional printing for anterior cervical surgery: a review.Journal of spine surgery (Hong Kong) · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveAccurate placement of cervical pedicle screws remains a surgical challenge. This study aimed to test the feasibility of using a novel three-dimensional (3D-)printed navigational template to overcome this challenge.
methodsCervical spines were scanned using computed tomography (CT). A 3D model of the cervical spines was created. The screw trajectory was designed to pass through the central axis of the pedicle. Thereafter, a navigational template was designed by removing the soft tissue from the bony surface in the 3D model. A 3D printer was used to print the navigational template. The screws were then placed in the cadavers following CT scanning. The 3D model of the designed trajectory and the placed screws were registered. The coordinates of the entry and exit points of the designed trajectory and the actual trajectory were recorded. The numbers of qualified points that met the different degrees of accuracy were compared using a χ
resultsA total of 158 screws were placed. Five screws breached the pedicle cortex with a distance <2 mm. There was no significant difference between the pre- and postoperative entry points with a degree of accuracy ≥1.7 mm (P = 0.131). Meanwhile, there was no significant difference between the pre- and postoperative exit points with degrees of accuracy ≥6.4 mm (P = 0.071).
conclusionA navigational template can be designed by removing the soft tissue from the bony surface in a CT-generated 3D model. This guiding tool may effectively prevent intraoperative drifting and accurately places cervical pedicle screws.