ArticleScientific reports2018
Optimizing critical parameters for the directly measurement of particle flow with PF-SIBS.
Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Quantification of toxic metals using machine learning techniques and spark emission spectroscopy.Atmospheric measurement techniques · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A novel measurement technology named as particle flow-spark induced breakdown spectroscopy (PF-SIBS) was reported for real-time measurement of solid materials. Critical measurement parameters of PF-SIBS were optimized and a set of fly ashes with different carbon content were measured for evaluation of measurement performance. Four electrode materials, tungsten, copper, molybdenum and platinum, were compared in the aspects of signal stability, line interference and electrode durability. Less line interference and better signal stability were obtained with W and Cu electrode, while W electrode has better durability. Quartz sand with diameters from 48 μm to 180 μm were tested to investigate the influence of particle size. As the particle diameter increased, the intensity of Si 288.16 nm line decreased while that of ambient air constituents increased. To reduce the particle effect, the sum intensity from sample and ambient air were introduced to correct. The RSD of line intensity between the five diameters were reduced from 67.30% to 16.59% with Cu electrodes and from 63.21% to 13.64% with W electrodes. With the optimal measurement parameters and correction, fly ash samples with different carbon content were tested and the correlation coefficients R
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.