Evidence map›Paper›PMID 29382011›Full record

SynthesisMedicine2017

Biodegradable polymer drug-eluting stents versus first-generation durable polymer drug-eluting stents: A systematic review and meta-analysis of 12 randomized controlled trials.

Pravesh Kumar Bundhun, Manish Pursun, Feng Huang

Abstract readComparative StudyMeta-AnalysisSystematic Review
In one paragraph

Synthesis in Medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Pravesh Kumar BundhunInstitute of Cardiovascular Diseases, the First Affiliated Hospital of Guangxi Medical University Guangxi Medical University Institute of Cardiovascular Diseases and Guangxi Key Laboratory Base of Precision Medicine in Cardio-cerebrovascular Diseases Control and Prevention, the First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, P. R. China.
Manish Pursun
Feng Huang

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEven if drug-eluting stents (DES) showed beneficial effects in patients with coronary artery diseases (CADs), limitations have been observed with the first-generation durable polymer DES (DP-DES). Recently, biodegradable polymer DES (BP-DES) have been approved to be used as an alternative to DP-DES, with potential benefits. We aimed to systematically compare BP-DES with the first-generation DP-DES using a large number of randomized patients.

methodsElectronic databases were searched for randomized controlled trials (RCTs) comparing BP-DES with first-generation DP-DES. The main endpoints were the long-term (≥2 years) adverse clinical outcomes that were reported with these 2 types of DES. We calculated odds ratios (ORs) with 95% confidence intervals (CIs) and the analysis was carried out by RevMan 5.3 software.

resultsTwelve trials with a total number of 13,480 patients (7730 and 5750 patients were treated by BP-DES and first-generation DP-DES, respectively) were included. During a long-term follow-up period of ≥2 years, mortality, myocardial infarction (MI), target lesion revascularization (TLR), and major adverse cardiac events (MACEs) were not significantly different between these 2 groups with OR: 0.84, 95% CI: 0.66-1.07; P = .16, I = 0%, OR: 1.01, 95% CI: 0.45-2.27; P = .98, I = 0%, OR: 0.91, 95% CI: 0.75-1.11; P = .37, I = 0% and OR: 0.86, 95% CI: 0.44-1.67; P = .65, I = 0%, respectively. Long-term total stent thrombosis (ST), definite ST, and probable ST were also not significantly different between BP-DES and the first-generation DP-DES with OR: 0.77, 95% CI: 0.50-1.18; P = .22, I = 0%, OR: 0.71, 95% CI: 0.43-1.18; P = .19, I = 0% and OR: 1.31, 95% CI: 0.56-3.08; P = .53, I = 6%, respectively.

conclusionLong-term mortality, MI, TLR, MACEs, and ST were not significantly different between BP-DES and the first-generation DP-DES. However, the follow-up period was restricted to only 3 years in this analysis.

Indexed as

Absorbable ImplantsCoronary Artery DiseaseDrug-Eluting StentsHumansPolymersPostoperative ComplicationsProsthesis DesignRandomized Controlled Trials as TopicTreatment OutcomePolymers

Identifiers

PMID29382011
PMCPMC5709010

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.