Radiotherapy setup displacements in breast cancer patients: 3D surface imaging experience.
Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 38 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
38 citing papers in PubMed.
- Crawl positioning improves set-up precision and patient comfort in prone whole breast irradiation.Scientific reports · 2020Trial
- Optimization of CBCT-guided imaging schedules for left-sided postmastectomy radiotherapy using VMAT: A dosimetric, radiobiological, and cost analysis.Journal of applied clinical medical physics · 2026Article
- Accuracy of surface-guided radiotherapy-based positioning and surface tracking in breast radiotherapy using a thermo-optical camera system.Physical and engineering sciences in medicine · 2026Article
- Operational assessment of tattooless breast radiotherapy using AlignRT surface guidance.Technical innovations & patient support in radiation oncology · 2025Article
- Setup Accuracy and Efficiency of Real-Time Video Assistance for Surface-Guided Positioning in Radiation Therapy of Right-Sided Locoregional Breast Cancer.Advances in radiation oncology · 2025Article
- Tattoo-less chest wall and regional nodal irradiation using surface imaging.Technical innovations & patient support in radiation oncology · 2025Article
- Planning Automation for Treatment Techniques Comparison and Robustness Analysis: Tangential Intensity Modulated Radiation Therapy and Volumetric Modulated Arc Therapy for Whole Breast Irradiation.Advances in radiation oncology · 2025Article
- A Low-Cost Optomechatronic Diffuse Optical Mammography System for 3D Image Reconstruction: Proof of Concept.Diagnostics (Basel, Switzerland) · 2025Article
- Reproducibility and stability of voluntary deep inspiration breath hold and free breath in breast radiotherapy based on real-time 3-dimensional optical surface imaging system.Radiation oncology (London, England) · 2024Article
- Personalized Deep Learning Model for Clinical Target Volume on Daily Cone Beam Computed Tomography in Breast Cancer Patients.Advances in radiation oncology · 2024Article
- Setup margins based on the inter- and intrafractional setup error of left-sided breast cancer radiotherapy using deep inspiration breath-hold technique (DIBH) and surface guided radiotherapy (SGRT).Journal of applied clinical medical physics · 2024Article
- Interfractional variation in whole-breast VMAT irradiation: a dosimetric study with complementary SGRT and CBCT patient setup.Radiation oncology (London, England) · 2024Article
- Surface-guided radiotherapy systems in locoregional deep inspiration breath hold radiotherapy for breast cancer - a multicenter study on the setup accuracy.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology · 2024Article
- Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system.Radiological physics and technology · 2023Article
- Comparison of setup accuracy of optical surface image versus orthogonal x-ray images for VMAT of the left breast using deep-inspiration breath-hold.Journal of applied clinical medical physics · 2023Article
- ESTRO-ACROP guideline for positioning, immobilisation and setup verification for local and loco-regional photon breast cancer irradiation.Technical innovations & patient support in radiation oncology · 2023Article
- Surface-Guided Radiotherapy: Can We Move on from the Era of Three-Point Markers to the New Era of Thousands of Points?Bioengineering (Basel, Switzerland) · 2023Review
- Dose coverage and breath-hold analysis of breast cancer patients treated with surface-guided radiotherapy.Radiation oncology (London, England) · 2023Article
- Evaluation of initial patient setup methods for breast cancer between surface-guided radiation therapy and laser alignment based on skin marking in the Halcyon system.Radiation oncology (London, England) · 2023Article
- Accuracy of a time-of-flight (ToF) imaging system for monitoring deep-inspiration breath-hold radiotherapy (DIBH-RT) for left breast cancer patients.Physical and engineering sciences in medicine · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aimIn this study, we intend to compare two different setup procedures for female breast cancer patients.
backgroundImaging in radiotherapy provides a precise localization of the tumour, increasing the accuracy of the treatment delivery in breast cancer. MATERIALS AND
methodsTwenty breast cancer patients who underwent whole breast radiotherapy (WBRT) were selected for this study. Patients were divided into two groups of ten. Group one (G1) was positioned by tattoos and then the patient positioning was adjusted with the aid of AlignRT (Vision RT, London, UK). In group two (G2), patients were positioned only by tattoos. For both groups, the first 15 fractions were analyzed, a daily kilovoltage (kV) cone beam computed tomography (CBCT) image was made and then the rotational and translational displacements and, posteriorly, the systematic (
resultsThe comparison of CBCT displacements for the two groups showed a statistically significant difference in the translational left-right (LR) direction (
conclusionsAlignRT could help the positioning of breast cancer patients; however, it should be used with another imaging method.