Evidence map›Paper›PMID 29378624›Full record

ArticleRadiation oncology (London, England)2018

Evaluation of the tumor movement and the reproducibility of two different immobilization setups for image-guided stereotactic body radiotherapy of liver tumors.

Constantin Dreher, Markus Oechsner, Michael Mayinger, Stefanie Beierl, Marciana-Nona Duma, Stephanie E Combs, Daniel Habermehl

Open access · goldAbstract read
In one paragraph

Article in Radiation oncology (London, England), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Technology in cancer research & treatment
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Constantin DreherDepartment of Radiation Oncology, University Hospital Rechts der Isar, Technical University München, Ismaningerstr. 22, 81675, Munich, Germany.
Markus OechsnerDepartment of Radiation Oncology, University Hospital Rechts der Isar, Technical University München, Ismaningerstr. 22, 81675, Munich, Germany.
Michael MayingerDepartment of Radiation Oncology, University Hospital Rechts der Isar, Technical University München, Ismaningerstr. 22, 81675, Munich, Germany.
Stefanie BeierlDepartment of Radiation Oncology, University Hospital Rechts der Isar, Technical University München, Ismaningerstr. 22, 81675, Munich, Germany.
Marciana-Nona DumaDepartment of Radiation Oncology, University Hospital Rechts der Isar, Technical University München, Ismaningerstr. 22, 81675, Munich, Germany.
Stephanie E CombsDepartment of Radiation Oncology, University Hospital Rechts der Isar, Technical University München, Ismaningerstr. 22, 81675, Munich, Germany.
Daniel HabermehlDepartment of Radiation Oncology, University Hospital Rechts der Isar, Technical University München, Ismaningerstr. 22, 81675, Munich, Germany. daniel.habermehl@tum.de.
Klinikum rechts der Isar · DEHelmholtz Zentrum München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purpose of this study is to evaluate the tumor movement and accuracy of patient immobilization in stereotactic body radiotherapy of liver tumors with low pressure foil or abdominal compression.

methodsFifty-four liver tumors treated with stereotactic body radiotherapy were included in this study. Forty patients were immobilized by a vacuum couch with low pressure foil, 14 patients by abdominal compression. We evaluated the ratio of gross tumor volume/internal target volume, the tumor movement in 4D-computed tomography scans and daily online adjustments after cone beam computed tomography scans.

resultsThe ratio of gross tumor volume/internal target volume was smaller with low pressure foil. The tumor movement in 4D-computed tomography scans was smaller with abdominal compression, the cranial movement even significantly different (p = 0.02). The mean online adjustments and their mean absolute values in the vertical, lateral and longitudinal axis were smaller with abdominal compression. The online adjustments were significantly different (p < 0.013), their absolute values in case of the longitudinal axis (p = 0.043). There was no significant difference of the adjustments' 3D vectors.

conclusionsIn comparison to low pressure foil, abdominal compression leads to a reduction of the tumor movement. Online adjustments decreased significantly, thus leading to higher accuracy in patient positioning.

Indexed as

HumansImmobilizationLiver NeoplasmsMovementPatient PositioningRadiosurgeryRadiotherapy, Image-GuidedReproducibility of ResultsLiver tumorPatient immobilizationRobustnessStereotactic body radiotherapy

Identifiers

PMID29378624
PMCPMC5789593
OpenAlexW2795375801

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.