Evidence map›Paper›PMID 29368180›Full record

ArticleDer Unfallchirurg2018

[Complications after intramedullary stabilization of clavicle fractures].

Alexander Eickhoff, Maximilian Fischer, Florian Gebhard, Christian Ehrnthaller

Abstract read
PubMed Publisher
In one paragraph

Article in Der Unfallchirurg, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.3field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 7 citations in OpenAlex.

  1. Pooled it
  2. A novel concept for splint fixation of midshaft clavicle fractures: a biomechanical feasibility study.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2026
    Article
  3. Efficacy of intramedullary bridge fixation for midshaft clavicle fractures: a retrospective analysis of a novel technique.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Alexander EickhoffKlinik für Unfall‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Ulm, Albert- Einstein-Allee 23, 89081, Ulm, Deutschland. alexander_eickhoff@yahoo.de.
Maximilian FischerKlinik für Unfall‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Ulm, Albert- Einstein-Allee 23, 89081, Ulm, Deutschland.
Florian GebhardKlinik für Unfall‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Ulm, Albert- Einstein-Allee 23, 89081, Ulm, Deutschland.
Christian EhrnthallerKlinik für Unfall‑, Plastische und Wiederherstellungschirurgie, Universitätsklinikum Ulm, Albert- Einstein-Allee 23, 89081, Ulm, Deutschland.
University Hospital Ulm · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOperative treatment of clavicle fractures by intramedullary nailing with titanium elastic nailing (TEN) has been established as an alternative to plate osteosynthesis for many years. The main complication after TEN osteosynthesis is nail migration. The goal of this study was evaluation of predictors for medial nail migration and comparison with plate osteosynthesis. MATERIAL AND

methodsA retrospective analysis of electronic patient charts, surgical protocols and radiographs of all operatively treated clavicle shaft fractures between 2010-2014 (n = 141) was performed. When evaluating the patient charts and the surgical protocols special attention was paid to the fracture type, the duration of the operation, the need for an open reduction and the onset of complications as well as the duration until implant removal. Radiographs were analyzed concerning the implant location and an implant migration.

resultsSurgery time (39 vs. 83 min) as well as the time to implant removal (226 vs. 495 days) were significantly reduced (p = 0.00), while complication (39% vs. 21.4%) as well as reoperation rates (15% vs. 7.1%; p = 0.033) were increased in TEN compared to plate osteosynthesis. The main complication was medial nail migration. The following predictors regarding medial migration could be identified: open or closed reduction (p = 0.021), multifragmentary fractures (p = 0.049), oblique fractures (p = 0.08) and TEN thickness (33% at 2 mm, 0% at 3 mm). DISCUSSION: Advantages of TEN are a shorter surgery time as well as a shorter duration until implant removal. The TEN osteosynthesis led to a significantly increased complication rate, with nail migration representing the major reason. When predictors for medial TEN migration are considered, type B and C fractures can also be sufficiently treated by a large diameter TEN.

Indexed as

Bone NailsClavicleFracture Fixation, IntramedullaryFracture HealingFractures, BoneHumansProsthesis FailureRetrospective StudiesTreatment OutcomeClavicle fractureComplicationIntramedullary nailingMedial migrationTEN

Identifiers

PMID29368180
OpenAlexW2792089781

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.