Evidence map›Paper›PMID 29359096›Full record

ArticleBiomedical optics express2018

Development of a real-time and quantitative thrombus sensor for an extracorporeal centrifugal blood pump by near-infrared light.

Daisuke Sakota, Tatsuki Fujiwara, Katsuhiro Ohuchi, Katsuyuki Kuwana, Hiroyuki Yamazaki, Ryo Kosaka, Masahiro Nishida, Tomohiro Mizuno, Hirokuni Arai, Osamu Maruyama

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.0field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Daisuke SakotaHealth Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba-shi, Ibaraki 305-8564, Japan.
Tatsuki FujiwaraDepartment of Cardiovascular Surgery, Tokyo Medical and Dental University Graduate School of Medical and Dental Sciences, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
Katsuhiro OhuchiDepartment of Advanced Surgical Technology Research and Development, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
Katsuyuki KuwanaSenko Medical Instrument Mfg. Co., Ltd., 3-23-13 Hongo, Bunkyo-ku, Tokyo 113-0033, Japan.
Hiroyuki YamazakiOptquest Co., Ltd., 1335 Haraichi, Ageo-shi, Saitama 362-0021, Japan.
Ryo KosakaHealth Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba-shi, Ibaraki 305-8564, Japan.
Masahiro NishidaHealth Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba-shi, Ibaraki 305-8564, Japan.
Tomohiro MizunoDepartment of Cardiovascular Surgery, Tokyo Medical and Dental University Graduate School of Medical and Dental Sciences, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
Hirokuni AraiDepartment of Cardiovascular Surgery, Tokyo Medical and Dental University Graduate School of Medical and Dental Sciences, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8519, Japan.
Osamu MaruyamaHealth Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 1-2-1 Namiki, Tsukuba-shi, Ibaraki 305-8564, Japan.
National Institute of Advanced Industrial Science and Technology · JPTokyo Medical and Dental University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We developed an optical thrombus sensor for a monopivot extracorporeal centrifugal blood pump. In this study, we investigated its quantitative performance for thrombus detection in acute animal experiments of left ventricular assist using the pump on pathogen-free pigs. Optical fibers were set in the driver unit of the pump. The incident light at the near-infrared wavelength of 810 nm was aimed at the pivot bearing, and the resulting scattered light was guided to the optical fibers. The detected signal was analyzed to obtain the thrombus formation level. As a result, real-time and quantitative monitoring of the thrombus surface area on the pivot bearing was achieved with an accuracy of 3.6 ± 2.3 mm

Indexed as

(170.0170) Medical optics and biotechnology(170.1470) Blood or tissue constituent monitoring

Identifiers

PMID29359096
PMCPMC5772574
OpenAlexW2775076721

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.