Evidence map›Paper›PMID 29357331›Full record

Trial reportPain physician2018

Reducing Radiation Exposure in Lumbar Transforaminal Epidural Steroid Injections with Pulsed Fluoroscopy: A Randomized, Double-blind, Controlled Clinical Trial.

Edward Braun, Andrew M Sack, Dawood Sayed, Smith Manion, Brian Hamm, Michael Brimacombe, Michael Tollette, Talal W Khan, Walter Orr, Andrea Nicol

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Pain physician, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.5field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 4 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Edward BraunUniversity of Kansas Medical Center, Kansas City, KS.
Andrew M SackUniversity of Kansas Medical Center, Kansas City, KS.
Dawood SayedUniversity of Kansas Medical Center, Kansas City, KS.
Smith ManionUniversity of Kansas Medical Center, Kansas City, KS.
Brian HammUniversity of Kansas Medical Center, Kansas City, KS.
Michael BrimacombeUniversity of Kansas Medical Center, Kansas City, KS.
Michael TolletteUniversity of Kansas Medical Center, Kansas City, KS.
Talal W KhanUniversity of Kansas Medical Center, Kansas City, KS.
Walter OrrUniversity of Kansas Medical Center, Kansas City, KS.
Andrea NicolUniversity of Kansas Medical Center, Kansas City, KS.
University of Kansas Medical Center · US

Funding

Central Nervous System Amplification in Lumbar Failed Back Surgery SyndromeK23GM123320 · NIGMS · UNIVERSITY OF KANSAS MEDICAL CENTER · PI CHADWICK, ANDREA LYNN · 2017 to 2022
$1.1M
NIGMS NIH HHS K23 GM123320
6 · The paper itself

Abstract

backgroundFluoroscopy-guided lumbar transforaminal epidural steroid injections (L-TFESI) result in radiation exposure that carries risks to patients, physicians, and procedural staff.

objectiveWe aim to evaluate the feasibility of using pulsed fluoroscopy to safely reduce radiation exposure during L-TFESI. STUDY

designThis is a prospective, double-blind, randomized controlled trial.

settingThis study took place in a single-center, academic, outpatient interventional pain management clinic.

methodsPatients undergoing L-TFESI were randomly assigned to either continuous mode fluoroscopy (high-dose), pulsed fluoroscopy with 8 pulses per second (medium-dose), or pulsed fluoroscopy with one pulse per second (low-dose). Data on radiation doses and other clinical and demographic factors were also collected.

resultsIn total, 231 cases were analyzed in the high-dose group (n = 81), medium-dose group (n = 72), and low-dose group (n = 78). Mean radiation effective dose (µSv) was 121 in the high-dose group, 57.9 in the medium-dose group, and 34.8 in the low-dose group (P < 0.001). The incidence of inadequate image quality in the pulsed groups was 6% (9/150). The body mass index (BMI, mean ± SD) was significantly higher in patients with inadequate image quality (37.3 ± 7.2) than with adequate quality (30.5 ± 7.2, P = 0.005). LIMITATIONS: Radiation doses were measured using the meter on C-arm fluoroscopes rather than by direct measurement.

conclusionsThe use of pulsed fluoroscopy during L-TFESI resulted in radiation dose reduction of up to 72.1% without causing any significant adverse events. Pulsed fluoroscopy should be considered as an initial fluoroscopic setting for L-TFESI to reduce radiation exposure. KEY WORDS: Radiation, epidural, fluoroscopy, injection, exposure, pulse.

Indexed as

AdultAgedDouble-Blind MethodFemaleFluoroscopyHumansIncidenceInjections, EpiduralMaleMiddle AgedProspective StudiesRadiation Exposure

Identifiers

PMID29357331
PMCPMC6413313
OpenAlexW2985986205

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.