ReviewJournal of spine surgery (Hong Kong)2017
Percutaneous screw placement in the lumbar spine with a modified guidance technique based on 3D CT navigation system.
Review in Journal of spine surgery (Hong Kong), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.
- Pedicle screw placement in spinal neurosurgery using a 3D-printed drill guide template: a systematic review and meta-analysis.Journal of orthopaedic surgery and research · 2020Pooled it
- Application of 3-dimensional printing guide template and pointed lotus-style regulator in percutaneous pedicle screw fixation for thoracolumbar fractures.Scientific reports · 2022Trial
- Evaluation of a Three-Dimensional Printed Guide and a Polyoxymethylene Thermoplastic Regulator for Percutaneous Pedicle Screw Fixation in Patients with Thoracolumbar Fracture.Medical science monitor : international medical journal of experimental and clinical research · 2020Trial
- Article
- Article
- Extended-wavelength diffuse reflectance spectroscopy dataset of animal tissues for bone-related biomedical applications.Scientific data · 2024Article
- Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022Article
- Perspective on the integration of optical sensing into orthopedic surgical devices.Journal of biomedical optics · 2022Article
- A real-time 3D electromagnetic navigation system for percutaneous pedicle screw fixation in traumatic thoraco-lumbar fractures: implications for efficiency, fluoroscopic time, and accuracy compared with those of conventional fluoroscopic guidance.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022Article
- The utilization of minimally invasive surgery techniques for the treatment of spinal deformity.Journal of spine surgery (Hong Kong) · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Several guidance techniques have been employed to increase accuracy and reduce surgical time during percutaneous placement of pedicle screws (PS). The purpose of our study was to present a modified technique for percutaneous placement of lumbar PS that reduces surgical time. We reviewed 23 cases of percutaneous PS placement using our technique for minimally invasive lumbar surgeries and 24 control cases where lumbar PS placement was done via common technique using Jamshidi needles (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). An integrated computer-guided navigation system was used in all cases. In the technique modification, a handheld drill with a navigated guide was used to create the path for inserting guidewires through the pedicles and into the vertebral bodies. After drill removal, placement of the guidewires through the pedicles took place. The PS were implanted over the guidewires, through the pedicles and into the vertebral bodies. Intraoperative computed tomography was performed after screw placement to ensure optimal positioning in all cases. There were no intraoperative complications with either technique. PS placement was correct in all cases. The average time for each PS placement was 6.9 minutes for the modified technique and 9.2 minutes for the common technique. There was no significant difference in blood loss. In conclusion, this modified technique is efficient and contributes to reduced operative time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.