Evidence map›Paper›PMID 29354745›Full record

ReviewJournal of spine surgery (Hong Kong)2017

Percutaneous screw placement in the lumbar spine with a modified guidance technique based on 3D CT navigation system.

Ioannis D Siasios, John Pollina, Asham Khan, Vassilios George Dimopoulos

Open access · hybridAbstract readReview
In one paragraph

Review in Journal of spine surgery (Hong Kong), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 1 pooled it
2.7field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 1 synthesis or guideline pooled it, 20 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Percutaneous thoraco-lumbar-sacral pedicle screw placement accuracy results from a multi-center, prospective clinical study using a skin marker-based optical navigation system.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022
    Article
  8. Article
  9. A real-time 3D electromagnetic navigation system for percutaneous pedicle screw fixation in traumatic thoraco-lumbar fractures: implications for efficiency, fluoroscopic time, and accuracy compared with those of conventional fluoroscopic guidance.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2022
    Article
  10. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Ioannis D SiasiosDepartment of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
John PollinaDepartment of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
Asham KhanDepartment of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
Vassilios George DimopoulosDepartment of Neurosurgery, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY, USA.
Buffalo General Medical Center · USUniversity at Buffalo, State University of New York · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Several guidance techniques have been employed to increase accuracy and reduce surgical time during percutaneous placement of pedicle screws (PS). The purpose of our study was to present a modified technique for percutaneous placement of lumbar PS that reduces surgical time. We reviewed 23 cases of percutaneous PS placement using our technique for minimally invasive lumbar surgeries and 24 control cases where lumbar PS placement was done via common technique using Jamshidi needles (Becton, Dickinson and Company, Franklin Lakes, NJ, USA). An integrated computer-guided navigation system was used in all cases. In the technique modification, a handheld drill with a navigated guide was used to create the path for inserting guidewires through the pedicles and into the vertebral bodies. After drill removal, placement of the guidewires through the pedicles took place. The PS were implanted over the guidewires, through the pedicles and into the vertebral bodies. Intraoperative computed tomography was performed after screw placement to ensure optimal positioning in all cases. There were no intraoperative complications with either technique. PS placement was correct in all cases. The average time for each PS placement was 6.9 minutes for the modified technique and 9.2 minutes for the common technique. There was no significant difference in blood loss. In conclusion, this modified technique is efficient and contributes to reduced operative time.

Indexed as

computed tomography (CT)navigationPedicle screws (PS)percutaneous technique

Identifiers

PMID29354745
PMCPMC5760416
OpenAlexW2775964622

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.