Evidence map›Paper›PMID 29354706›Full record

ArticleBMJ open ophthalmology2017

In vivo crystalline lens measurements with novel swept-source optical coherent tomography: an investigation on variability of measurement.

Takuhei Shoji, Naoko Kato, Sho Ishikawa, Hisashi Ibuki, Norihiro Yamada, Itaru Kimura, Kei Shinoda

Abstract read
In one paragraph

Article in BMJ open ophthalmology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 41 papers.

0numbers the graph read from it
0cells of the map it votes in
41citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

41 citing papers in PubMed.

  1. Crystalline Lens Shape During Accommodation in Children.Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists) · 2026
    Article
  2. Observational
  3. Article
  4. Article
  5. Article
  6. Crystalline lens power and astigmatism calculation in myopia by swept-source optical coherence tomography: A pilot study.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2025
    Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Swept-source optical coherence tomography and ultrasound biomicroscopy study of anterior segment parameters in primary angle-closure glaucoma.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2023
    Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Takuhei ShojiDepartment of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan.
Naoko KatoDepartment of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan.
Sho IshikawaDepartment of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan.
Hisashi IbukiDepartment of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan.
Norihiro YamadaDepartment of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan.
Itaru KimuraDepartment of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan.
Kei ShinodaDepartment of Ophthalmology, Saitama Medical University, Iruma, Saitama, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate the reproducibility of in vivo crystalline lens measurements obtained by novel commercially available swept-source (SS) optical coherence tomography (OCT) specifically designed for anterior segment imaging. METHODS AND ANALYSIS: One eye from each of 30 healthy subjects was randomly selected using the CASIA2 (Tomey, Nagoya, Japan) in two separate visits within a week. Each eye was imaged twice. After image scanning, the anterior and posterior lens curvatures and lens thickness were calculated automatically by the CASIA2 built-in program at 0 dioptre (D) (static), -1 D, -3 D and -5 D accommodative stress. The intraobserver and intervisit reproducibility coefficient (RC) and intraclass correlation coefficient (ICC) were calculated.

resultsThe intraobserver and intervisit RCs ranged from 0.824 to 1.254 mm and 0.789 to 0.911 mm for anterior lens curvature, from 0.276 to 0.299 mm and 0.221 to 0.270 mm for posterior lens curvature and from 0.065 to 0.094 mm and 0.054 to 0.132 mm for lens thickness, respectively. The intraobserver and intervisit ICCs ranged from 0.831 to 0.865 and 0.828 to 0.914 for anterior lens curvature, from 0.832 to 0.898 and 0.840 to 0.933 for posterior lens curvature and from 0.980 to 0.992 and 0.942 to 0.995 for lens thickness. High ICC values were observed for each measurement regardless of accommodative stress. RCs in younger subjects tended to be larger than those in older subjects.

conclusionsThis novel anterior segment SS-OCT instrument produced reliable in vivo crystalline lens measurement with good repeatability and reproducibility regardless of accommodation stress.

Indexed as

imagingLens and zonules

Identifiers

PMID29354706
PMCPMC5721637

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked