Evidence map›Paper›PMID 29351261›Full record

ArticleSensors (Basel, Switzerland)2018

Three-Dimensional Terahertz Coded-Aperture Imaging Based on Single Input Multiple Output Technology.

Shuo Chen, Chenggao Luo, Bin Deng, Hongqiang Wang, Yongqiang Cheng, Zhaowen Zhuang

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Shuo ChenSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. chenshuo_nudt@163.com.ORCID 0000-0001-9398-0009
Chenggao LuoSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. luochenggao@nudt.edu.cn.
Bin DengSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. dengbin_nudt@163.com.
Hongqiang WangSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. oliverwhq@tom.com.
Yongqiang ChengSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. nudtyqcheng@gmail.com.ORCID 0000-0002-0127-384X
Zhaowen ZhuangSchool of Electronic Science, National University of Defense Technology, Changsha 410073, China. zwzhuang@nudt.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

As a promising radar imaging technique, terahertz coded-aperture imaging (TCAI) can achieve high-resolution, forward-looking, and staring imaging by producing spatiotemporal independent signals with coded apertures. In this paper, we propose a three-dimensional (3D) TCAI architecture based on single input multiple output (SIMO) technology, which can reduce the coding and sampling times sharply. The coded aperture applied in the proposed TCAI architecture loads either purposive or random phase modulation factor. In the transmitting process, the purposive phase modulation factor drives the terahertz beam to scan the divided 3D imaging cells. In the receiving process, the random phase modulation factor is adopted to modulate the terahertz wave to be spatiotemporally independent for high resolution. Considering human-scale targets, images of each 3D imaging cell are reconstructed one by one to decompose the global computational complexity, and then are synthesized together to obtain the complete high-resolution image. As for each imaging cell, the multi-resolution imaging method helps to reduce the computational burden on a large-scale reference-signal matrix. The experimental results demonstrate that the proposed architecture can achieve high-resolution imaging with much less time for 3D targets and has great potential in applications such as security screening, nondestructive detection, medical diagnosis, etc.

Indexed as

coded-aperture imagingsingle input multiple output (SIMO)terahertzthree-dimensional (3D)

Identifiers

PMID29351261
PMCPMC5795760

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.