Evidence map›Paper›PMID 29348570›Full record

ArticleScientific reports2018

Systematic in vivo evaluation of the time-dependent inflammatory response to steel and Teflon insulin infusion catheters.

Jasmin R Hauzenberger, Julia Münzker, Petra Kotzbeck, Martin Asslaber, Vladimir Bubalo, Jeffrey I Joseph, Thomas R Pieber

Erratum issuedOpen access · goldAbstract read
In one paragraph

Article in Scientific reports, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 25 papers.

0numbers the graph read from it
0cells of the map it votes in
25citing papers in PubMed
2.1field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

25 citing papers in PubMed, 38 citations in OpenAlex.

  1. Trial
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Development of the Extended Infusion Set and Its Mechanism of Action.Journal of diabetes science and technology · 2024
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Insulin Derived Fibrils Induce CytotoxicityJournal of diabetes science and technology · 2023
    Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Jasmin R HauzenbergerDepartment of Internal Medicine, Division of Endocrinology and Diabetology, Medical University of Graz, Graz, Austria.
Julia MünzkerDepartment of Internal Medicine, Division of Endocrinology and Diabetology, Medical University of Graz, Graz, Austria.
Petra KotzbeckDepartment of Internal Medicine, Division of Endocrinology and Diabetology, Medical University of Graz, Graz, Austria.
Martin AsslaberInstitute of Pathology, Medical University of Graz, Graz, Austria.
Vladimir BubaloDivision of Biomedical Research, Medical University of Graz, Graz, Austria.
Jeffrey I JosephDepartment of Anesthesiology, Jefferson Artificial Pancreas Center, Thomas Jefferson University, Philadelphia, PA, USA.
Thomas R PieberDepartment of Internal Medicine, Division of Endocrinology and Diabetology, Medical University of Graz, Graz, Austria. endo@medunigraz.at.
Medical University of Graz · ATThomas Jefferson University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Continuous subcutaneous insulin infusion (CSII) catheters are considered the weak link of insulin pump therapy. Wear-time considerably varies between patients and the choice of catheter material is based on personal preferences rather than scientific facts. Therefore, we systematically assessed and quantified the inflammatory tissue response to steel versus Teflon CSII catheters over a maximum wear-time of 7 days in swine. Tissue surrounding catheters was analysed using histopathology and quantitative real-time PCR. The area of inflammation increased significantly over time independent of material which was confirmed by an increase in CD68 expression and an increase in mononuclear and neutrophil cell infiltrate around the catheters. We observed substantially higher fibrin deposition (p < 0.05) around steel on day 4 of wear-time. IL-6 gene expression increased within 24 hours after insertion, returned to normal levels around Teflon (p < 0.05) but remained high around steel (p < 0.05). IL-10 and TGF-β levels did not resolve over time, indicating impaired wound healing. In conclusion, there was a major temporal effect in the acute inflammatory response to CSII catheters but we found little difference between materials. This study setup presents a robust tool for the systematic analysis of the tissue response to CSII catheters.

Indexed as

PolytetrafluoroethyleneSteelAnimalsBiomarkersBiopsyCathetersFemaleImmunohistochemistryInflammationInflammation MediatorsInsulin Infusion SystemsMaleSwineBiomarkersInflammation MediatorsPolytetrafluoroethyleneSteel

Identifiers

PMID29348570
PMCPMC5773511
OpenAlexW2784126038

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked