ArticlePloS one2018
Sensitivity and specificity of two dried blood spot methods for HIV-1 viral load monitoring among patients in Hanoi, Vietnam.
Article in PloS one, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.
- The performance of using dried blood spot specimens for HIV-1 viral load testing: A systematic review and meta-analysis.PLoS medicine · 2022Pooled it
- Brief Report: Undetectable HIV-1 Viral Load Among Virally Suppressed People Living With HIV: Implications for Undetectable Equals Untransmittable (U=U) in Resource-Limited Settings Using Dried Spot Testing.Journal of acquired immune deficiency syndromes (1999) · 2025Article
- HIV-1 drug resistance genotyping success rates and correlates of Dried-blood spots and plasma specimen genotyping failure in a resource-limited setting.BMC infectious diseases · 2022Article
- Study To Evaluate the Performance of a Point-of-Care Whole-Blood HIV Viral Load Test (SAMBA II HIV-1 Semi-Q Whole Blood).Journal of clinical microbiology · 2021Article
- The Development of a Standardized Quality Assessment Material to Support XpertDiagnostics (Basel, Switzerland) · 2021Article
- Cost and Impact of Dried Blood Spot Versus Plasma Separation Card for Scale-up of Viral Load Testing in Resource-limited Settings.Clinical infectious diseases : an official publication of the Infectious Diseases Society of America · 2020Article
- Comparison of Alere q whole blood viral load with DBS and plasma viral load in the classification of HIV virological failure.PloS one · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 4 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The use of dried blood spot (DBS) specimens for HIV viral load (VL) monitoring is recommended to support the roll-out of routine VL monitoring in low and middle income countries (LMICs). To better understand the use of DBS for VL monitoring, we evaluated two DBS testing methods, Roche TaqMan® Free Virus Evolution protocol (DBS-FVE) and Roche TaqMan® SPEX protocol (DBS-SPEX)) in patients receiving ART at an HIV clinic in Hanoi, Vietnam. Sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) were calculated for each DBS testing method at the thresholds of 1000 and 5000 copies/ml compared to plasma VL. At a threshold of 1000 copies/ml, sensitivity, specificity, PPV and NPV of the DBS-SPEX method were 98.8% (95% CI: 93.3%-100%), 74.3% (95% CI: 70.8%-77.5%), 31.5% (95% CI: 25.8%-37.6%), and 99.8% (95% CI: 98.9%-100%), respectively. Increasing the VL threshold value to 5000 copies/ml improved specificity (97.9% CI: 96.6%-98.9%) and PPV (83.9% CI: 74.5%-90.9%). Using the DBS-FVE method, at the threshold of 1000 copies/ml and with a correction factor of +0.3 log copies/ml, sensitivity was 95.1% (87.8%-98.6%) and specificity was 98.8% (97.7%-99.5%). Sensitivity decreased at the threshold of 5000 copies/ml (65.8%, 95% CI: 54.3%-76.1%). With a correction factor of +0.7 log copies/ml, the sensitivity was 96.3% (89.6%-99.2%) and specificity was 98.2% (96.9%-99.1%) at the threshold of 1000 copies/ml. We found that the Roche DBS-FVE method, with a +0.7 log copies/ml correction factor, performed well with sensitivity and specificity greater than 96% at a VL threshold of 1000 copies/m. These findings add to the growing body of evidence supporting the use of DBS VL testing for ART monitoring. Future research should evaluate the association between VL results by DBS and clinical outcome measures such as HIV drug resistance, morbidity, and mortality.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.