Potential effects of low-dose average CT on cardiac implantable electronic devices.

Emily Y Pan, Dershan Luo, Tinsu Pan

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors.

Emily Y PanDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Unit 1352, Houston, TX, 70030-4009, USA.
Dershan LuoDepartment of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas, 70030, USA.
Tinsu PanDepartment of Imaging Physics, The University of Texas MD Anderson Cancer Center, 1515 Holcombe Blvd., Unit 1352, Houston, TX, 70030-4009, USA. tpan@mdanderson.org.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAverage CT has been shown to be more accurate than conventional helical CT in quantitation of the PET data. The risk of CT irradiation of a cardiac implantable electronic device (CIED) causing an adverse event is low and is generally outweighed by the clinical benefit of a medically indicated examination. However, irradiation of CIED over one breath cycle in cine CT scan for average CT could impose risks on a patient who is pacing dependent. The purpose of this study was to demonstrate that low-dose average CT can be safe for CIED.

methodsA Medtronic CIED of model Protecta VR was submerged in a saline bath for a series of 4-s cine CT scans on a GE CT scanner programmed to deliver a 2-cm-wide radiation at a dose rate of 0.9 to 41.2 mGy/s to the CIED. The number of over-sensings was recorded as the interference of radiation to the CIED.

resultsDose rates ≥ 1.9 mGy/s caused over-sensing. The higher the dose rate, the more over-sensings there were. The lowest dose rate of 0.9 mGy/s did not cause any over-sensing.

conclusionsLow-dose average CT at 0.9 mGy/s can be safe for a CIED patient who is pacing dependent.

Indexed as

Aged, 80 and overComputer SimulationDefibrillators, ImplantableEquipment DesignFour-Dimensional Computed TomographyHumansMalePacemaker, ArtificialPatient SafetyReproducibility of ResultsRiskThyroid NeoplasmsTomography, X-Ray Computedcomputed tomography (CT)myocardial perfusion imaging: PETPET/CT imaging