Evidence map›Paper›PMID 29340989›Full record

ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2019

Gated SPECT myocardial perfusion imaging with cadmium-zinc-telluride detectors allows real-time assessment of dobutamine-stress-induced wall motion abnormalities.

Rene Nkoulou, Mathias Wolfrum, Aju P Pazhenkottil, Michael Fiechter, Ronny R Buechel, Oliver Gaemperli, Philipp A Kaufmann

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2019. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Update of the Brazilian Guideline on Nuclear Cardiology - 2020.Arquivos brasileiros de cardiologia · 2020
    Guideline
  2. Article
  3. Real-time gated-SPECT myocardial perfusion imaging with CZT detectors: A promising tool for monitoring left ventricular function.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

Rene NkoulouDepartment of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland. rene.nkoulou@hcuge.ch.
Mathias WolfrumDepartment of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
Aju P PazhenkottilDepartment of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
Michael FiechterDepartment of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
Ronny R BuechelDepartment of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
Oliver GaemperliDepartment of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.
Philipp A KaufmannDepartment of Nuclear Medicine, University Hospital Zurich, Rämistrasse 100, 8091, Zurich, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundLeft ventricular (LV) ejection fraction (EF) during high dobutamine stress (HD) by real-time gated-SPECT myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride (CZT) gamma camera was validated versus cardiac magnetic resonance imaging (CMR). METHODS AND

resultsAfter injecting 99mTc-tetrofosmin (320 MBq) in 50 patients (mean age 64 +/- 11 years), EF at rest and post-stress as well as relevant changes in EF at HD (ΔEF ≥ 5%) were assessed. CZT and CMR rest EF values yielded an excellent correlation and agreement (r = 0.96; P < 0.001; Bland-Altman limits of agreement (BA): + 0 to 14.8%). HD EF acquisition was feasible using CZT and correlated better to HD CMR EF than did post-stress CZT EF (r = 0.85 vs 0.76, respectively, all P < 0.001). Agreement in ΔEF detection between HD CMR and immediate post-stress CZT (reflecting standard acquisition using conventional SPECT camera unable to scan during stress) was 45%, while this increased to 85% with real-time HD CZT scan.

conclusionReal-time ultrafast dobutamine gated-SPECT MPI with a CZT device is feasible and provides accurate measurements of HD LV performance.

Indexed as

MovementMyocardial Perfusion ImagingTomography, Emission-Computed, Single-PhotonAgedCadmiumDobutamineFeasibility StudiesFemaleGamma CamerasHeart VentriclesHumansMagnetic Resonance ImagingMaleMiddle AgedMyocardial ContractionOrganophosphorus CompoundsCadmiumCdZnTeDobutamineOrganophosphorus CompoundsOrganotechnetium Compoundstechnetium tc-99m tetrofosminTelluriumZincCadmium-zinc-telluride detectors gamma cameraDobutamine-stressWall motion abnormalities

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.