Evidence map›Paper›PMID 29332454›Full record

ArticleTechnology in cancer research & treatment2017

Intrafractional Tracking Accuracy of a Transperineal Ultrasound Image Guidance System for Prostate Radiotherapy.

Amy S Yu, Mohammad Najafi, Dimitre H Hristov, Tiffany Phillips

Abstract read
In one paragraph

Article in Technology in cancer research & treatment, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. On the feasibility of transperineal 3D ultrasound image guidance for robotic radical prostatectomy.International journal of computer assisted radiology and surgery · 2019
    Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Amy S YuDepartment of Radiation Oncology, Stanford University School of Medicine, Stanford University, Stanford, CA, USA.
Mohammad NajafiDepartment of Radiation Oncology, Stanford University School of Medicine, Stanford University, Stanford, CA, USA.
Dimitre H Hristov *Department of Radiation Oncology, Stanford University School of Medicine, Stanford University, Stanford, CA, USA.
Tiffany Phillips *Department of Radiation Oncology, Stanford University School of Medicine, Stanford University, Stanford, CA, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of this study is to evaluate the tracking accuracy of a commercial ultrasound system under relevant treatment conditions and demonstrate its clinical utility for detecting significant treatment deviations arising from inadvertent intrafractional target motion.

methodsA multimodality male pelvic phantom was used to simulate prostate image-guided radiotherapy with the system under evaluation. Target motion was simulated by placing the phantom on a motion platform. The tracking accuracy of the ultrasound system was evaluated using an independent optical tracking system under the conditions of beam-on, beam-off, poor image quality with an acoustic shadow introduced, and different phantom motion cycles. The time delay between the ultrasound-detected and actual phantom motion was investigated. A clinical case example of prostate treatment is presented as a demonstration of the utility of the system in practice.

resultsTime delay between the motion phantom and ultrasound tracking system is 223 ± 45.2 milliseconds including video and optical tracking system frame rates. The tracking accuracy and precision were better with a longer period. The precision of ultrasound tracking performance in the axial (superior-inferior) direction was better than that in the lateral (left-right) direction (root mean square errors are 0.18 and 0.25 mm, respectively). The accuracy of ultrasound tracking performance in the lateral direction was better than that in the axial direction (the mean position errors are 0.23 and 0.45 mm, respectively). Interference by radiation and image quality do not affect tracking ability significantly. Further, utilizing the tracking system as part of a clinical study for prostate treatment further verified the accuracy and clinical appropriateness.

conclusionsIt is feasible to use transperineal ultrasound daily to monitor prostate motion during treatment. Our results verify the accuracy and precision of an ultrasound system under typical external beam treatment conditions and further demonstrate that the tracking system was able to identify important prostate shifts in a clinical case.

Indexed as

Phantoms, ImagingHumansImaging, Three-DimensionalMaleModels, TheoreticalProstateProstatic NeoplasmsRadiotherapy DosageRadiotherapy, Image-GuidedUltrasonographyimage-guided radiation therapyintrafractional imagingmotion trackingtime lagtransperineal ultrasound

Identifiers

PMID29332454
PMCPMC5762073

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.