Evidence map›Paper›PMID 29324699›Full record

ArticleSensors (Basel, Switzerland)2018

LED-CT Scan for pH Distribution on a Cross-Section of Cell Culture Medium.

Nobuya Higashino, Toshio Takayama, Hiroaki Ito, Mitsuhiro Horade, Yasutaka Yamaguchi, Chia-Hung Dylan Tsai, Makoto Kaneko

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.1field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 8 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Nobuya HigashinoDepartment of Mechanical Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan. higashino@hh.mech.eng.osaka-u.ac.jp.
Toshio TakayamaDepartment of Mechanical Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan. takayama@mech.eng.osaka-u.ac.jp.
Hiroaki ItoDepartment of Mechanical Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan. ito@hh.mech.eng.osaka-u.ac.jp.
Mitsuhiro HoradeDepartment of Mechanical Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan. horade@mech.eng.osaka-u.ac.jp.
Yasutaka YamaguchiDepartment of Mechanical Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan. yamaguchi@mech.eng.osaka-u.ac.jp.
Chia-Hung Dylan TsaiDepartment of Mechanical Engineering, National Chiao Tung University, 1001 University Road, Hsinchu 300, Taiwan. dylantsai@nctu.edu.tw.ORCID 0000-0002-8840-3984
Makoto KanekoDepartment of Mechanical Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan. mk@mech.eng.osaka-u.ac.jp.
The University of Osaka · JPNational Yang Ming Chiao Tung University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In cell culture, the pH of the culture medium is one of the most important conditions. However, the culture medium may have non-uniform pH distribution due to activities of cells and changes in the environment. Although it is possible to measure the pH distribution with an existing pH meter using distributed electrodes, the method involves direct contact with the medium and would greatly increase the risk of contamination. Here in this paper, we propose a computed tomography (CT) scan for measuring pH distribution using the color change of phenol red with a light-emitting diode (LED) light source. Using the principle of CT scan, we can measure pH distribution without contacting culture medium, and thus, decrease the risk of contamination. We have developed the device with a LED, an array of photo receivers and a rotation mechanism. The system is firstly calibrated with different shapes of wooden objects that do not pass light, we succeeded in obtaining their 3D topographies. The system was also used for measuring a culture medium with two different pH values, it was possible to obtain a pH distribution that clearly shows the boundary.

Indexed as

Cell Culture TechniquesCulture MediaDrug ContaminationHydrogen-Ion ConcentrationTomography, X-Ray ComputedCulture Mediacell culturenon-contact measurementpH measurement

Identifiers

PMID29324699
PMCPMC5795824
OpenAlexW2783633457

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked