Surgical Dynamometer to Simultaneously Measure the Tension Forces and the Distance between Wound Edges during the Closure of a Laparotomy.
Article in Sensors (Basel, Switzerland), 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- Biomechanical Parameters of Mesh Reinforcement and Analysis of a Novel Device for Incisional Hernia Prevention.The Journal of surgical research · 2021Article
- Quantifying fascial tension in ventral hernia repair and component separation.Hernia : the journal of hernias and abdominal wall surgery · 2021Article
- Miniaturized Sensors Registering the Long-Term Course of Suture Tension In Vivo under Varying Intra-Abdominal Pressure.Sensors (Basel, Switzerland) · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The closure of the abdominal wall after making a laparotomy is a major challenge for surgeons, since a significant percentage of closures fail and incisional hernias rise. The suture has to withstand the forces required to close the incision, while not hindering the adequate wound healing progression. Currently, there is no surgical measuring device that could be used to determine the required closing forces, which can be very different depending on the patient. This paper presents a dynamometer to measure the tension forces to be applied while closing a surgical incision, and it simultaneously measures the distance between wound edges. It is a compass-like instrument. A mechanism between the two legs incorporates a load cell, whose signal is read by an electronic device that computes the values of the tension forces between wound edges. An angular position sensor at the pin joint between legs provides the distance between both sides of the incision. Measuring capabilities of the instrument prototype were verified at the laboratory. Thereafter, its functionality was demonstrated in experimental surgery tests. Therefore, the instrument could be very useful in clinical applications, assisting personalized surgical techniques.