ArticleAnesthesia and analgesia2018
Life Cycle Assessment and Costing Methods for Device Procurement: Comparing Reusable and Single-Use Disposable Laryngoscopes.
Article in Anesthesia and analgesia, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 85 papers, 5 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
85 citing papers in PubMed, 5 syntheses or guidelines pooled it, 238 citations in OpenAlex.
- Economic impact of disposable versus reusable instruments in minimally invasive surgery: a systematic review.Surgical endoscopy · 2026Pooled it
- Evidence-based Integration of Environmental Sustainability into Clinical Guidelines for Operating Rooms: A Systematic Review.Annals of surgery · 2026Pooled it
- The carbon footprints of single-use and reusable medical devices: a systematic review.BMJ open · 2025Pooled it
- Behavioural change interventions encouraging clinicians to reduce carbon emissions in clinical activity: a systematic review.BMC health services research · 2023Pooled it
- The impact of switching from single-use to reusable healthcare products: a transparency checklist and systematic review of life-cycle assessments.European journal of public health · 2023Pooled it
- Sustainability indicators for gastrointestinal endoscopy: a framework proposed by the Canadian Association of Gastroenterology and the American Society for Gastrointestinal Endoscopy.Journal of the Canadian Association of Gastroenterology · 2026Article
- Comparing environmental footprints of haemodialysis and online haemodiafiltration in Italy.International urology and nephrology · 2026Article
- Choosing reusable operating theatre devices at an Australian health service avoids hundreds of tonnes of waste and could save millions of dollars per annum.Anaesthesia and intensive care · 2026Article
- Environmental footprint of open versus laparoscopic inguinal hernia repair.Hernia : the journal of hernias and abdominal wall surgery · 2026Article
- Choosing Wisely Canada climate-conscious recommendations for critical care medicine.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026Article
- Article
- Environmental sustainability evidence in critical care medicine: a scoping review.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2026Article
- Second Chances: A Pediatric Orthopaedic Society of North America Survey and Review of Current Practices and Attitudes Toward the Reuse of Deep Orthopaedic Implants.Journal of the Pediatric Orthopaedic Society of North America · 2026Article
- Attitudes, knowledge, practices, and perceived barriers on sustainability actions among Italian anesthesiologists-intensivists: a nationwide survey.Journal of anesthesia, analgesia and critical care · 2026Article
- Theoretically redesigning peritoneal dialysis products for sustainability: A life cycle inventory approach.The International journal of artificial organs · 2026Article
- Climate resilience as a strategic lever for long-term healthcare sustainability: a narrative review.British journal of anaesthesia · 2026Review
- Contribution of hospitals and clinical services to global warming: a scoping systematic review.Frontiers in public health · 2026Article
- Comparative environmental impact analysis of screening tests for colorectal cancer: a single-centre life cycle assessment.BMJ public health · 2026Article
- Safety, cost and environmental impact of reprocessing low and moderate risk single-use medical devices: a systematic review.GMS hygiene and infection control · 2026Review
- Human Factors in Airway Management: Designing Systems for Safer, Team-Based Care.Journal of clinical medicine · 2025Review
25 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
Authors and funding
3 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundTraditional medical device procurement criteria include efficacy and safety, ease of use and handling, and procurement costs. However, little information is available about life cycle environmental impacts of the production, use, and disposal of medical devices, or about costs incurred after purchase. Reusable and disposable laryngoscopes are of current interest to anesthesiologists. Facing mounting pressure to quickly meet or exceed conflicting infection prevention guidelines and oversight body recommendations, many institutions may be electively switching to single-use disposable (SUD) rigid laryngoscopes or overcleaning reusables, potentially increasing both costs and waste generation. This study provides quantitative comparisons of environmental impacts and total cost of ownership among laryngoscope options, which can aid procurement decision making to benefit facilities and public health.
methodsWe describe cradle-to-grave life cycle assessment (LCA) and life cycle costing (LCC) methods and apply these to reusable and SUD metal and plastic laryngoscope handles and tongue blade alternatives at Yale-New Haven Hospital (YNHH). The US Environmental Protection Agency's Tool for the Reduction and Assessment of Chemical and other environmental Impacts (TRACI) life cycle impact assessment method was used to model environmental impacts of greenhouse gases and other pollutant emissions.
resultsThe SUD plastic handle generates an estimated 16-18 times more life cycle carbon dioxide equivalents (CO2-eq) than traditional low-level disinfection of the reusable steel handle. The SUD plastic tongue blade generates an estimated 5-6 times more CO2-eq than the reusable steel blade treated with high-level disinfection. SUD metal components generated much higher emissions than all alternatives. Both the SUD handle and SUD blade increased life cycle costs compared to the various reusable cleaning scenarios at YNHH. When extrapolated over 1 year (60,000 intubations), estimated costs increased between $495,000 and $604,000 for SUD handles and between $180,000 and $265,000 for SUD blades, compared to reusables, depending on cleaning scenario and assuming 4000 (rated) uses. Considering device attrition, reusable handles would be more economical than SUDs if they last through 4-5 uses, and reusable blades 5-7 uses, before loss.
conclusionsLCA and LCC are feasible methods to ease interpretation of environmental impacts and facility costs when weighing device procurement options. While management practices vary between institutions, all standard methods of cleaning were evaluated and sensitivity analyses performed so that results are widely applicable. For YNHH, the reusable options presented a considerable cost advantage, in addition to offering a better option environmentally. Avoiding overcleaning reusable laryngoscope handles and blades is desirable from an environmental perspective. Costs may vary between facilities, and LCC methodology demonstrates the importance of time-motion labor analysis when comparing reusable and disposable device options.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.