ArticleNeurogastroenterology and motility2018
Inter-rater agreement of novel high-resolution impedance manometry metrics: Bolus flow time and esophageal impedance integral ratio.
Article in Neurogastroenterology and motility, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed.
- Dysphagia is Associated With the Combination of Defective Bolus Transit and Poorly Relaxing Lower Esophageal Sphincter in Patients With Ineffective Esophageal Motility.Journal of neurogastroenterology and motility · 2026Article
- Future perspectives in esophageal manometry.World journal of gastrointestinal surgery · 2025Review
- The Clinical Usefulness of Functional Luminal Imaging Probe in Esophageal Dysmotility Disorder.Journal of neurogastroenterology and motility · 2022Article
- Normative values of intra-bolus pressure and esophageal compliance based on 4D high-resolution impedance manometry.Neurogastroenterology and motility · 2022Article
- Deep learning-based artificial intelligence model for identifying swallow types in esophageal high-resolution manometry.Neurogastroenterology and motility · 2022Article
- A multi-stage machine learning model for diagnosis of esophageal manometry.Artificial intelligence in medicine · 2022Article
- A deep-learning-based unsupervised model on esophageal manometry using variational autoencoder.Artificial intelligence in medicine · 2021Article
- Four-dimensional impedance manometry derived from esophageal high-resolution impedance-manometry studies: a novel analysis paradigm.Therapeutic advances in gastroenterology · 2020Article
- New Developments in Esophageal Motility Testing.Current treatment options in gastroenterology · 2019Review
- High-resolution impedance manometry parameters in the evaluation of esophageal function of non-obstructive dysphagia patients.Neurogastroenterology and motility · 2019Article
- Improved Assessment of Bolus Clearance in Patients With Achalasia Using High-Resolution Impedance Manometry.Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
backgroundNovel high-resolution impedance manometry (HRIM) metrics of bolus flow time (BFT) and esophageal impedance integral (EII) ratio have demonstrated clinical utility, though the reliability of their analysis has not been assessed. We aimed to evaluate the inter-rater agreement of the BFT and EII ratio.
methodsHRIM studies including five upright, liquid swallows from 40 adult patients were analyzed by two raters using a customized MATLAB program to generate the BFT and EII ratio. Inter-rater agreement was assessed using the intraclass correlation coefficient (ICC) for median values generated per patient and also for all 200 swallows. KEY
resultsThe ICC (95% confidence interval, CI) for BFT was 0.873 (0.759-0.933) for median values and 0.838 (0.778-0.881) for all swallows. The ICC (95% CI) for EII ratio was 0.983 (0.968-0.991) for median values and 0.905 (0.875-0.928) for all swallows. Median values for both BFT and EII ratio were similar between the two raters (P-values .05). CONCLUSIONS AND INFERENCES: The BFT and EII ratio can be reliably calculated as supported by generally excellent inter-rater agreement. Thus, broader utilization of these measures appears feasible and would facilitate further evaluation of their clinical utility.