Evidence map›Paper›PMID 29317923›Full record

ArticlePharmacy practice

Identification of inhaler technique errors with a routine procedure in Portuguese community pharmacy.

M Margarida Castel-Branco, Ana Fontes, Isabel V Figueiredo

Open access · diamondAbstract read
In one paragraph

Article in Pharmacy practice. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 2 pooled it
2.2field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 2 syntheses or guidelines pooled it, 28 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Review
  10. Article
  11. A comparative analysis of errors in inhaler technique among COPD versus asthma patients.International journal of chronic obstructive pulmonary disease
    Observational
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

M Margarida Castel-BrancoLaboratory of Pharmacology and Pharmaceutical Care, Faculty of Pharmacy, University of Coimbra, Coimbra (Portugal). mmcb@ci.uc.pt.ORCID 0000-0002-6533-9932
Ana FontesLaboratory of Pharmacology and Pharmaceutical Care, Faculty of Pharmacy, University of Coimbra, Coimbra, (Portugal). AnaFontes_11@hotmail.com.
Isabel V FigueiredoLaboratory of Pharmacology and Pharmaceutical Care, Faculty of Pharmacy, University of Coimbra, Coimbra (Portugal). isabel.vitoria@netcabo.pt.ORCID 0000-0003-0127-4575
University of Coimbra · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA correct selection of drugs prescribed, but also the choice of the appropriate inhaler device, is crucial for the control of respiratory diseases.

objectiveTo evaluate the inhaler technique and identify potential errors of patients when treated with inhalers by testing a routinary procedure to be implemented in any community pharmacy.

methodsAdults with asthma/COPD and under inhalation therapy were invited to demonstrate how they use their inhalers. After direct observation it was registered whether all the sequential steps included in the summary of product characteristics (SmPC) were performed.

resultsThe study involved 67 patients from 4 community pharmacies (Portugal central region): 34 (50.7%) males, 65.4 (SD=18.28) years old, 42 (62.7%) with COPD, and 23 (34.3%) using more than one inhaler. The 67 patients used 95 inhalers, comprising: 57 (60.0%) multiple dose DPI (dry powder inhalers), 18 (18.9%) single dose DPI, 16 (16.8%) pMDI (pressurized metered dose inhalers), 2 (2.1%) pMDI+spacer and 2 (2.1%) SMI (soft mist inhalers). No errors were made only by 9 (13.4%) patients. In the 75 DPIs techniques, the most frequent errors were 'no previous forced expiration' (46=61.3%) and 'no 10s apnea after inhalation' (51=68.0%); in the 16 pMDIs techniques common errors were 'lack of hand-lung coordination' (7=43.8 %), 'no previous forced exhalation' (8=50.0%) and 'no apnea after inhalation' (10=62.5%). After inhaling from 56 devices containing corticosteroids, 34 (60.7%) of the patients did not wash their mouth.

conclusionThe study demonstrated the possibility of performing this procedure routinely in Portuguese community pharmacies and also its utility, since 58 (87%) of patients had at least one error during the inhalers use.

Indexed as

AsthmaChronic ObstructiveHealth CareNebulizers and VaporizersPatient Education as TopicPharmaciesPharmacistsPortugalPulmonary DiseaseQuality Assurance

Identifiers

PMID29317923
PMCPMC5742000
OpenAlexW2775721772

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked