Evidence map›Paper›PMID 29310670›Full record

ArticleJournal of orthopaedic surgery and research2018

The comparison of clinical outcome of fresh type II odontoid fracture treatment between anterior cannulated screws fixation and posterior instrumentation of C1-2 without fusion: a retrospective cohort study.

Suomao Yuan, Bin Wei, Yonghao Tian, Jun Yan, Wanlong Xu, Lianlei Wang, Xinyu Liu

Open access · goldAbstract readComparative StudyEvaluation Study
In one paragraph

Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
3.8field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it, 37 citations in OpenAlex.

  1. The impact of odontoid screw fixation techniques on screw-related complications and fusion rates: a systematic review and meta-analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021
    Pooled it
  2. Article
  3. Comparison of EMG responses obtained from endotracheal tube and thyroid cartilage surface electrodes in thyroidectomies performed with intraoperative nerve monitoring.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Reevaluation of a classification system: stable and unstable odontoid fractures in geriatric patients-a radiological outcome measurement.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Treatment of type II odontoid fracture in the elderly.Journal of surgical case reports · 2020
    Article
  18. Observational
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Suomao YuanSpine Center, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, People's Republic of China.
Bin WeiReproductive Medicine Centre, Maternal and Child Health Care Hospital of Shandong Province, Key Laboratory of Birth Regulation and Control Technology of National Health and Family Planning Commission of China, Jinan, 250014, People's Republic of China.
Yonghao TianSpine Center, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, People's Republic of China.
Jun YanSpine Center, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, People's Republic of China.
Wanlong XuSpine Center, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, People's Republic of China.
Lianlei WangSpine Center, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, People's Republic of China.
Xinyu LiuSpine Center, Qilu Hospital of Shandong University, Wenhua West Road 107#, Jinan, 250012, People's Republic of China. cnia56993895615@126.com.
Qilu Hospital of Shandong University · CNNational Health and Family Planning Commission · CN

Funding

Science and Technology Development Plan Project of Shandong Province 2015WS0303
6 · The paper itself

Abstract

backgroundRecently, the excellent outcomes of temporary fixation of C1-2 without fusion in the treatment of odontoid fracture had been reported. It is still unclear if this technique could achieve the equivalent outcomes as the golden standard technique of anterior screw fixation. The objective of this study is to compare the clinical outcome of two treatments of fresh type II odontoid fracture: anterior cannulated screws fixation (ACSF) versus posterior instrumentation of C1-2 without fusion (PIWF).

methodsThis is a retrospective study. This series included 28 males and 8 females, and the mean age was 41.5 years (range, 22 to 70 years). Eleven patients were treated with ACSF, and 25 patients with PIWF. For PIWF, the implants were removed after fracture union was confirmed at 0.75~1.5 years later. All patients underwent preoperative and serial postoperative clinical examinations at approximately 3 months, 6 months, and annually thereafter. The neck disability index (NDI) was used to assess the neck discomfort caused by the operation. The range of rotary motion was evaluated at each visit. All fractures were reassessed postoperatively with serial X-films and CT scans of the cervical spine at each follow-up visit, to evaluate screw position, fracture alignment, and fusion status.

resultsAll patients achieved immediate spinal stabilization after surgery, and none experienced neurologic deterioration. The follow-up periods ranged from 24 to 60 months. The average range of neck rotation was dramatically lost in PIWF after fixation (46° and 89° respectively in ACSF and PIWF), and recovered to 83° after the implant was removed. The NDI in PIWF was statistically higher than that in ACSF (5 and 13% respectively in ACSF and PIWF) after the first operation and decreased to 8% 1 year after the secondary operation. The fusion rates were 90.9 and 96% respectively in ACSF and PIWF. Both groups had a case of fracture non-union.

conclusionsFor fresh type II odontoid fractures, high rate of fracture union can be achieved by both ACSF and PIWF. For most fresh type II odontoid fractures, anterior screw fixation was the best option for its simplicity and preservation of normal atlanto-axial rotary function. Posterior instrumentation without fusion could preserve most of the atlanto-axial rotary function and lead to moderate neck discomfort and is also a good alternative if anterior screw fixation is contraindicated.

Indexed as

Bone ScrewsAdultAgedCervical VertebraeFemaleFracture Fixation, InternalFracture HealingHead MovementsHumansMaleMiddle AgedOdontoid ProcessRadiographyRange of Motion, ArticularRetrospective StudiesSpinal FracturesAnteriorFreshOdontoid fractureOutcomePosteriorType II

Identifiers

PMID29310670
PMCPMC5759802
OpenAlexW2783361855

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.