ArticleJournal of orthopaedic surgery and research2018
The comparison of clinical outcome of fresh type II odontoid fracture treatment between anterior cannulated screws fixation and posterior instrumentation of C1-2 without fusion: a retrospective cohort study.
Article in Journal of orthopaedic surgery and research, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 1 synthesis or guideline pooled it, 37 citations in OpenAlex.
- The impact of odontoid screw fixation techniques on screw-related complications and fusion rates: a systematic review and meta-analysis.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2021Pooled it
- Bilateral Medial Medullary Syndrome Following Anterior Odontoid Screw Fixation for a Type II Fracture: A Case Report.Journal of orthopaedic case reports · 2026Article
- Comparison of EMG responses obtained from endotracheal tube and thyroid cartilage surface electrodes in thyroidectomies performed with intraoperative nerve monitoring.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2026Article
- Anterior Odontoid Screw Fixation for Trauma: Case Series and Technical Considerations.Journal of clinical medicine · 2025Article
- Low-cost Posterior C1-C2 Fusion Using Sublaminar Wiring in Neurologically Intact Young Patient with Type IIA Odontoid Fracture: A Resource-oriented Approach.Journal of neurological surgery reports · 2025Article
- Two-screw osteosynthesis is biomechanically superior to single-screw osteosynthesis for type II odontoid fractures.Scientific reports · 2024Article
- Feasibility of Two-Screw Anterior Fixation for Odontoid Fractures in a Chinese Population: A Morphometric Study Based on Computed Tomography.Clinics in orthopedic surgery · 2023Article
- Feasibility of Anterior Fixation with Single Screw for Odontoid Fractures in Pediatrics: A Computed Tomographic Study.Orthopaedic surgery · 2023Article
- Regional variations in C1-C2 bone density on quantitated computed tomography and clinical implications.North American Spine Society journal · 2023Article
- Reevaluation of a classification system: stable and unstable odontoid fractures in geriatric patients-a radiological outcome measurement.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2022Article
- Full-Endoscopic Anterior Odontoid Screw Fixation: A Novel Surgical Technique.Orthopaedic surgery · 2022Article
- Anterior screw fixation for type II odontoid process fractures: A single-center experience with the double Herbert screw fixation technique (Retrospective cohort study).Annals of medicine and surgery (2012) · 2022Article
- Healing process of Type II odontoid fractures after C1-C2 posterior screw fixation: Predictive factors for pseudoarthrosis.Surgical neurology international · 2022Article
- Bilateral medial medullary syndrome following anterior screw fixation of type 2 odontoid fracture, a case report of two patients.Spinal cord series and cases · 2021Article
- A new tool in percutaneous anterior odontoid screw fixation.BMC musculoskeletal disorders · 2021Article
- Fractures of C2 (Axis) Vertebra: Clinical Presentation and Management.International journal of spine surgery · 2020Article
- Treatment of type II odontoid fracture in the elderly.Journal of surgical case reports · 2020Article
- Observational
- A Comparison of different posterior arthrodesis techniques versus anterior dens screw for odontoid fractures: A systematic review and meta-analysis.Journal of craniovertebral junction & spineReview
- Clinical and radiological union rate evaluation of type 2 odontoid fractures: A comparison between anterior screw fixation and halo vest in elderly patients.Journal of craniovertebral junction & spineArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundRecently, the excellent outcomes of temporary fixation of C1-2 without fusion in the treatment of odontoid fracture had been reported. It is still unclear if this technique could achieve the equivalent outcomes as the golden standard technique of anterior screw fixation. The objective of this study is to compare the clinical outcome of two treatments of fresh type II odontoid fracture: anterior cannulated screws fixation (ACSF) versus posterior instrumentation of C1-2 without fusion (PIWF).
methodsThis is a retrospective study. This series included 28 males and 8 females, and the mean age was 41.5 years (range, 22 to 70 years). Eleven patients were treated with ACSF, and 25 patients with PIWF. For PIWF, the implants were removed after fracture union was confirmed at 0.75~1.5 years later. All patients underwent preoperative and serial postoperative clinical examinations at approximately 3 months, 6 months, and annually thereafter. The neck disability index (NDI) was used to assess the neck discomfort caused by the operation. The range of rotary motion was evaluated at each visit. All fractures were reassessed postoperatively with serial X-films and CT scans of the cervical spine at each follow-up visit, to evaluate screw position, fracture alignment, and fusion status.
resultsAll patients achieved immediate spinal stabilization after surgery, and none experienced neurologic deterioration. The follow-up periods ranged from 24 to 60 months. The average range of neck rotation was dramatically lost in PIWF after fixation (46° and 89° respectively in ACSF and PIWF), and recovered to 83° after the implant was removed. The NDI in PIWF was statistically higher than that in ACSF (5 and 13% respectively in ACSF and PIWF) after the first operation and decreased to 8% 1 year after the secondary operation. The fusion rates were 90.9 and 96% respectively in ACSF and PIWF. Both groups had a case of fracture non-union.
conclusionsFor fresh type II odontoid fractures, high rate of fracture union can be achieved by both ACSF and PIWF. For most fresh type II odontoid fractures, anterior screw fixation was the best option for its simplicity and preservation of normal atlanto-axial rotary function. Posterior instrumentation without fusion could preserve most of the atlanto-axial rotary function and lead to moderate neck discomfort and is also a good alternative if anterior screw fixation is contraindicated.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.