ArticlePediatric cardiology2018
Feasibility and Validity of Printing 3D Heart Models from Rotational Angiography.
Article in Pediatric cardiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 35 citations in OpenAlex.
- Virtual 3D reconstruction of complex congenital cardiac anatomy from 3D rotational angiography.3D printing in medicine · 2025Article
- Augmented Reality Visualization of 3D Rotational Angiography in Congenital Heart Disease: A Comparative Study to Standard Computer Visualization.Pediatric cardiology · 2024Article
- Clinical situations for which 3D printing is considered an appropriate representation or extension of data contained in a medical imaging examination: pediatric congenital heart disease conditions.3D printing in medicine · 2024Review
- Accuracy and feasibility in building a personalized 3D printed femoral pseudoaneurysm model for endovascular training.PloS one · 2024Article
- Patient-Specific 3D-Printed Low-Cost Models in Medical Education and Clinical Practice.Micromachines · 2023Review
- Patient-Specific 3D-Printed Models in Pediatric Congenital Heart Disease.Children (Basel, Switzerland) · 2023Review
- Translating Imaging Into 3D Printed Cardiovascular Phantoms: A Systematic Review of Applications, Technologies, and Validation.JACC. Basic to translational science · 2022Review
- 3D Virtual Reality Imaging of Major Aortopulmonary Collateral Arteries: A Novel Diagnostic Modality.World journal for pediatric & congenital heart surgery · 2021Article
- The Histamine HBiomolecules · 2021Article
- 3D Printing-A Cutting Edge Technology for Treating Post-Infarction Patients.Life (Basel, Switzerland) · 2021Review
- 3D Printing for Cardiovascular Applications: From End-to-End Processes to Emerging Developments.Annals of biomedical engineering · 2021Review
- Quantitative Assessment of 3D Printed Model Accuracy in Delineating Congenital Heart Disease.Biomolecules · 2021Article
- 3D Modeling and Printing in Congenital Heart Surgery: Entering the Stage of Maturation.Frontiers in pediatrics · 2021Review
- Personalized Interventions: A Reality in the Next 20 Years or Pie in the Sky.Pediatric cardiology · 2020Review
- Advanced Medical Use of Three-Dimensional Imaging in Congenital Heart Disease: Augmented Reality, Mixed Reality, Virtual Reality, and Three-Dimensional Printing.Korean journal of radiology · 2020Review
- Dimensional Accuracy and Clinical Value of 3D Printed Models in Congenital Heart Disease: A Systematic Review and Meta-Analysis.Journal of clinical medicine · 2019Review
- Personalized Three-Dimensional Printed Models in Congenital Heart Disease.Journal of clinical medicine · 2019Review
Corrections and comments
- Erratum issued
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Rotational angiography (RA) has proven to be an excellent method for evaluating congenital disease (CHD) in the cardiac cath lab, permitting acquisition of 3D datasets with superior spatial resolution. This technique has not been routinely implemented for 3D printing in CHD. We describe our case series of models printed from RA and validate our technique. All patients with models printed from RA were selected. RA acquisitions from a Toshiba Infinix-I system were postprocessed and printed with a Stratasys Eden 260. Two independent observers measured 5-10 points of interest on both the RA and the 3D model. Bland Altman plot was used to compare the measurements on rotational angiography to the printed model. Models were printed from RA in 5 patients (age 2 months-1 year). Diagnoses included (a) coronary artery aneurysm, (b) Glenn shunt, (c) coarctation of the aorta, (d) tetralogy of Fallot with MAPCAs, and (e) pulmonary artery stenosis. There was no significant measurement difference between RA and the printed model (r = 0.990, p < 0.01, Bland Altman p = 0.987). There was also no significant inter-observer variability. The MAPCAs model was referenced by the surgeon intraoperatively and was accurate. Rotational angiography can generate highly accurate 3D models in congenital heart disease, including in small vascular structures. These models can be extremely useful in patient evaluation and management.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.