ArticlePLoS neglected tropical diseases2018
Establishing Ebola Virus Disease (EVD) diagnostics using GeneXpert technology at a mobile laboratory in Liberia: Impact on outbreak response, case management and laboratory systems strengthening.
Article in PLoS neglected tropical diseases, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 53 citations in OpenAlex.
- Ebola virus disease in the modern era: pathogenesis, therapeutic advances, vaccine strategies, and global health preparedness.Infection · 2026Review
- Vacuum Oven Drying: A Cost-Effective Way of Producing Field-Deployable Reagents for In-house Real-Time PCR Methods.Molecular biotechnology · 2025Article
- Public-private partnerships are critical for rapid response to infectious disease threats.Frontiers in public health · 2025Article
- Existing operational standards for field deployments of rapid response mobile laboratories: a scoping review.Frontiers in public health · 2024Article
- Study on bioaerosol diffusion and deposition in a mobile BSL-4 laboratory based on air age analysis.Journal of building engineering · 2023Article
- Mobile SARS‑CoV‑2 screening facilities for rapid deployment and university-based diagnostic laboratory.Engineering in life sciences · 2023Article
- Impact of Fast SARS-CoV-2 Molecular Point-Of-Care Testing on Patients' Length of Stay in an Emergency Department.Microbiology spectrum · 2022Article
- Glycosylated gold nanoparticles in point of care diagnostics: from aggregation to lateral flow.Chemical Society reviews · 2022Review
- The Evolution of Medical Countermeasures for Ebola Virus Disease: Lessons Learned and Next Steps.Vaccines · 2022Article
- Article
- Rapid establishment of a frontline field laboratory in response to an imported outbreak of Ebola virus disease in western Uganda, June 2019.PLoS neglected tropical diseases · 2021Article
- Ultrasensitive point-of-care immunoassay for secreted glycoprotein detects Ebola infection earlier than PCR.Science translational medicine · 2021Article
- Laboratory diagnosis of emerging human coronavirus infections - the state of the art.Emerging microbes & infections · 2020Review
- Assessing a novel, lab-free, point-of-care test for SARS-CoV-2 (CovidNudge): a diagnostic accuracy study.The Lancet. Microbe · 2020Article
- European Union training programme for tuberculosis laboratory experts: design, contribution and future direction.BMC health services research · 2020Article
- An open-source molecular diagnostic platform approach for outbreak and epidemic preparedness.African journal of laboratory medicine · 2020Article
- Uncrewed aircraft systems versus motorcycles to deliver laboratory samples in west Africa: a comparative economic study.The Lancet. Global health · 2020Article
- Development and Evaluation of a DuoMicroorganisms · 2019Article
- Article
- Ebola virus: A global public health menace: A narrative review.Journal of family medicine and primary care · 2019Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
20 authors at 4 institutions in 3 countries.
Funding
Abstract
The 2014-16 Ebola Virus Disease (EVD) outbreak in West Africa highlighted the necessity for readily available, accurate and rapid diagnostics. The magnitude of the outbreak and the re-emergence of clusters of EVD cases following the declaration of interrupted transmission in Liberia, reinforced the need for sustained diagnostics to support surveillance and emergency preparedness. We describe implementation of the Xpert Ebola Assay, a rapid molecular diagnostic test run on the GeneXpert platform, at a mobile laboratory in Liberia and the subsequent impact on EVD outbreak response, case management and laboratory system strengthening. During the period of operation, site coordination, management and operational capacity was supported through a successful collaboration between Ministry of Health (MoH), World Health Organization (WHO) and international partners. A team of Liberian laboratory technicians were trained to conduct EVD diagnostics and the laboratory had capacity to test 64-100 blood specimens per day. Establishment of the laboratory significantly increased the daily testing capacity for EVD in Liberia, from 180 to 250 specimens at a time when the effectiveness of the surveillance system was threatened by insufficient diagnostic capacity. During the 18 months of operation, the laboratory tested a total of 9,063 blood specimens, including 21 EVD positives from six confirmed cases during two outbreaks. Following clearance of the significant backlog of untested EVD specimens in November 2015, a new cluster of EVD cases was detected at the laboratory. Collaboration between surveillance and laboratory coordination teams during this and a later outbreak in March 2016, facilitated timely and targeted response interventions. Specimens taken from cases during both outbreaks were analysed at the laboratory with results informing clinical management of patients and discharge decisions. The GeneXpert platform is easy to use, has relatively low running costs and can be integrated into other national diagnostic algorithms. The technology has on average a 2-hour sample-to-result time and allows for single specimen testing to overcome potential delays of batching. This model of a mobile laboratory equipped with Xpert Ebola test, staffed by local laboratory technicians, could serve to strengthen outbreak preparedness and response for future outbreaks of EVD in Liberia and the region.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.