Evidence map›Paper›PMID 29292717›Full record

ArticleSensors (Basel, Switzerland)2017

Evaluation of Pressure Capacitive Sensors for Application in Grasping and Manipulation Analysis.

Paola Pessia, Francesca Cordella, Emiliano Schena, Angelo Davalli, Rinaldo Sacchetti, Loredana Zollo

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 7 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Paola PessiaUnit of Biomedical Robotics and Biomicrosystems, University Campus Bio-Medico of Rome, via Alvaro del Portillo 21, 00128 Rome, Italy. paola.pessia@alcampus.it.
Francesca CordellaUnit of Biomedical Robotics and Biomicrosystems, University Campus Bio-Medico of Rome, via Alvaro del Portillo 21, 00128 Rome, Italy. f.cordella@unicampus.it.
Emiliano SchenaUnit of Measurements and Biomedical Instrumentation, University Campus Bio-Medico of Rome, via Alvaro del Portillo 21, 00128 Rome, Italy. e.schena@unicampus.it.ORCID 0000-0002-9696-1265
Angelo DavalliCentro Protesi INAIL, Via Rabuina 14, 40054 Budrio (BO), Italy. a.davalli@inail.it.
Rinaldo SacchettiCentro Protesi INAIL, Via Rabuina 14, 40054 Budrio (BO), Italy. r.sacchetti@inail.it.
Loredana ZolloUnit of Biomedical Robotics and Biomicrosystems, University Campus Bio-Medico of Rome, via Alvaro del Portillo 21, 00128 Rome, Italy. l.zollo@unicampus.it.
Università Campus Bio-Medico · ITIstituto Nazionale per l'Assicurazione Contro gli Infortuni sul Lavoro · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The analysis of the human grasping and manipulation capabilities is paramount for investigating human sensory-motor control and developing prosthetic and robotic hands resembling the human ones. A viable solution to perform this analysis is to develop instrumented objects measuring the interaction forces with the hand. In this context, the performance of the sensors embedded in the objects is crucial. This paper focuses on the experimental characterization of a class of capacitive pressure sensors suitable for biomechanical analysis. The analysis was performed in three loading conditions (Distributed load, 9 Tips load, and Wave-shaped load, thanks to three different inter-elements) via a traction/compression testing machine. Sensor assessment was also carried out under human- like grasping condition by placing a silicon material with the same properties of prosthetic cosmetic gloves in between the sensor and the inter-element in order to simulate the human skin. Data show that the input-output relationship of the analyzed, sensor is strongly influenced by both the loading condition (i.e., type of inter-element) and the grasping condition (with or without the silicon material). This needs to be taken into account to avoid significant measurement error. To go over this hurdle, the sensors have to be calibrated under each specific condition in order to apply suitable corrections to the sensor output and significantly improve the measurement accuracy.

Indexed as

Hand StrengthGloves, ProtectiveHandHumansRoboticscapacitive pressure sensorgrasping and manipulation analysissensor characterization

Identifiers

PMID29292717
PMCPMC5750746
OpenAlexW2772654891

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.