Evidence map›Paper›PMID 29283343›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2018

Cardiac Lesion Mapping In Vivo Using Intracardiac Myocardial Elastography.

Ethan Bunting, Clement Papadacci, Elaine Wan, Vincent Sayseng, Julien Grondin, Elisa E Konofagou

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Intracardiac Echocardiography during Invasive Electrophysiological Procedures: a Scientific Statement of the European Heart Rhythm Association of the ESC, and the European Association of Percutaneous Cardiovascular Interventions of the ESC.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2026
    Guideline
  2. Impact of ablation on regional strain from 4D computed tomography in the left atrium.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025
    Article
  3. Article
  4. Article
  5. Catheter Ablation Lesion Visualization With Intracardiac Strain Imaging in Canines and Humans.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2020
    Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ethan Bunting
Clement Papadacci
Elaine Wan
Vincent Sayseng
Julien Grondin
Elisa E Konofagou

Funding

EARLY DETECTION AND MAPPING OF ISCHEMIA USING MYOCARDIAL ELASTOGRAPHYR01EB006042 · NIBIB · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI KONOFAGOU, ELISA E. · 2006 to 2018
$4.3M
Noninvasive arrhythmia mapping using Electromechanical Wave ImagingR01HL114358 · NHLBI · COLUMBIA UNIV NEW YORK MORNINGSIDE · PI KONOFAGOU, ELISA E. · 2012 to 2016
$1.9M
NHLBI NIH HHS R01 HL114358NIBIB NIH HHS R01 EB006042
6 · The paper itself

Abstract

Radio frequency (RF) ablation of the myocardium is used to treat various cardiac arrhythmias. The size, spacing, and transmurality of lesions have been shown to affect the success of the ablation procedure; however, there is currently no method to directly image the size and formation of ablation lesions in real time. Intracardiac myocardial elastography (ME) has been previously used to image the decrease in cardiac strain during systole in the ablated region as a result of the lesion formation. However, the feasibility of imaging multiple lesions and identifying the presence of gaps between lesions has not yet been investigated. In this paper, RF ablation lesions ( ) were generated in the left ventricular epicardium in three anesthetized canines. Two sets of two lesions each were created in close proximity to one another with small gaps (1.5 and 4 cm), while one set of two lesions was created directly next to each other with no gap. A clinical intracardiac echocardiography system was programmed to transmit a custom diverging beam sequence at 600 Hz and used to image the ablation site before and after the induction of ablation lesions. Cumulative strains were estimated over systole using a normalized cross-correlational displacement algorithm and a least-squares strain kernel. Afterward, lesions were excised and subjected to tetrazolium chloride staining. Results indicate that intracardiac ME was capable of imaging the reduction in systolic strain associated with the formation of an ablation lesion. Furthermore, lesion sets containing gaps were able to be distinguished from lesion sets created with no gaps. These results indicate that the end-systolic strain measured using intracardiac ME may be used to image the formation of lesions induced during an RF ablation procedure, in order to provide critical assessment of lesion viability during the interventional procedure.

Indexed as

AnimalsCatheter AblationDogsElasticity Imaging TechniquesEpicardial MappingHeartHeart Ventricles

Identifiers

PMID29283343
PMCPMC5747324

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.