ArticleKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2018

Patient-specific instrumentation in Oxford unicompartmental knee arthroplasty is reliable and accurate except for the tibial rotation.

B Kerens, A M Leenders, M G M Schotanus, B Boonen, W E Tuinebreijer, P J Emans, B Jong, N P Kort

Abstract read
PubMed Publisher
In one paragraph

Article in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

B KerensAZ St Maarten, Duffel, Belgium.
A M LeendersZuyderland Medical Centre, Sittard-Geleen, The Netherlands.
M G M SchotanusZuyderland Medical Centre, Sittard-Geleen, The Netherlands. martijnschotanus@hotmail.com.ORCID http://orcid.org/0000-0002-3975-6337
B BoonenMaastricht University Medical Centre, Maastricht, The Netherlands.
W E TuinebreijerErasmus MC, Rotterdam, The Netherlands.
P J EmansMaastricht University Medical Centre, Maastricht, The Netherlands.
B JongZuyderland Medical Centre, Sittard-Geleen, The Netherlands.
N P KortACIBADEM International Medical Center, Amsterdam, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposePatient-specific instrumentation (PSI) is a technique to plan and position the prosthesis components in unicompartmental knee arthroplasty (UKA) surgery. This study assesses whether the definitive component position in the frontal, sagittal and axial plane is according to the preoperative plan, based on the hypothesis that PSI is accurate.

methodsTwenty-six patients who had PSI Oxford UKA surgery were included prospectively. The component position in vivo was determined with a postoperative CT-scan and compared with the planned component position using MRI-based digital 3D imaging. Adjustments to the preoperative plan and implanted component sizes during surgery were recorded.

resultsIntraoperatively, no femoral adjustments were performed; 12 tibial re-resections were necessary. The median absolute deviation from the plan in degrees (range) in the frontal, sagittal and axial plane was 1.8° (- 1.5°-6.5°), 2.0° (- 6.5°-8.0°) and 1.0° (- 1.5°-5.0°) for the femoral component, and 2.5° (- 1.0°-6.0°), 3.0° (- 1.0°-5.0°) and 5.0° (- 6.5°-12.5°) for the tibial component. The femoral component is positioned 0.5 (- 1°-2.5°) mm more lateral and 0.8 (- 1.0°-2.5°) mm more anterior. The tibial component is positioned 2.0 (- 5.0-0.0) mm more lateral and 1.3 (- 3.0-6.0) mm more distal. The femoral and tibial default plans were changed four times (15.4%) and nine times (34.6%), respectively, before approval by the surgeon.

conclusionPSI in Oxford UKA surgery is reliable and accurately translates the preoperative plan into the in vivo situation, except for the tibial rotational position. The preoperative planning is a crucial step in avoiding re-resections that can cause angular deviations in prosthesis position, especially in tibial component rotational position. It is advised to avoid re-resections and to consider this while planning the PSI procedure. LEVEL OF EVIDENCE: Prospective comparative study Level II.

Indexed as

Knee ProsthesisAgedArthroplasty, Replacement, KneeBone MalalignmentFemaleFemurHumansKnee JointMaleMiddle AgedOsteoarthritis, KneeProspective StudiesReproducibility of ResultsRotationSurgery, Computer-AssistedTibiaAccuracyOxford kneePatient specific guidingPreoperative planUnicompartmental knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.