Evidence map›Paper›PMID 29276799›Full record

ArticleIEEE transactions on radiation and plasma medical sciences2017

Optimization of an Adaptive SPECT System with the Scanning Linear Estimator.

Nasrin Ghanbari, Eric Clarkson, Matthew Kupinski, Xin Li

Abstract read
In one paragraph

Article in IEEE transactions on radiation and plasma medical sciences, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Can patient-specific acquisition protocol improve performance on defect detection task in myocardial perfusion SPECT?Proceedings of SPIE--the International Society for Optical Engineering · 2024
    Article
  2. Ideal-Observer Computation with anthropomorphic phantoms using Markov chain Monte Carlo.Proceedings. IEEE International Symposium on Biomedical Imaging · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Nasrin GhanbariCollege of Optical Sciences, University of Arizona, Tucson, AZ, 85721 USA.
Eric ClarksonCollege of Optical Sciences, University of Arizona, Tucson, AZ, 85721 USA.
Matthew KupinskiCollege of Optical Sciences, University of Arizona, Tucson, AZ, 85721 USA.
Xin LiCollege of Optical Sciences, University of Arizona, Tucson, AZ, 85721 USA.

Funding

CENTER FOR GAMMA RAY IMAGINGP41EB002035 · NIBIB · UNIVERSITY OF ARIZONA · PI BARRETT, HARRISON H, FURENLID, LARS R · 2003 to 2018
$17.7M
SPECT Imaging and Parallel ComputingR01EB000803 · NIBIB · UNIVERSITY OF ARIZONA · PI CAUCCI, LUCA · 2012 to 2020
$4.2M
Graduate Training in Biomedical Imaging SpectrocopyT32EB000809 · NIBIB · UNIVERSITY OF ARIZONA · PI GMITRO, ARTHUR F. · 2003 to 2018
$3.3M
NIBIB NIH HHS P41 EB002035NIBIB NIH HHS R01 EB000803NIBIB NIH HHS T32 EB000809
6 · The paper itself

Abstract

A method for optimization of an adaptive Single Photon Emission Computed Tomography (SPECT) system is presented. Adaptive imaging systems can quickly change their hardware configuration in response to data being generated in order to improve image quality for a specific task. In this work we simulate an adaptive SPECT system and propose a method for finding the adaptation that maximizes the performance on a signal estimation task. To start with, a simulated object model containing a spherical signal is imaged with a scout configuration. A Markov-Chain Monte Carlo (MCMC) technique utilizes the scout data to generate an ensemble of possible objects consistent with the scout data. This object ensemble is imaged by numerous simulated hardware configurations and for each system estimates of signal activity, size and location are calculated via the Scanning Linear Estimator (SLE). A figure of merit, based on a Modified Dice Index (MDI), quantifies the performance of each imaging configuration and it allows for optimization of the adaptive SPECT. This figure of merit is calculated by multiplying two terms: the first term uses the definition of the Dice similarity index to determine the percent of overlap between the actual and the estimated spherical signal, the second term utilizes an exponential function that measures the squared error for the activity estimate. The MDI combines the error in estimates of activity, size, and location, in one convenient metric and it allows for simultaneous optimization of the SPECT system with respect to all the estimated signal parameters. The results of our optimizations indicate that the adaptive system performs better than a non-adaptive one in conditions where the diagnostic scan has a low photon count - on the order of thousand photons per projection. In a statistical study, we optimized the SPECT system for one hundred unique objects and demonstrated that the average MDI on an estimation task is 0.84 for the adaptive system and 0.65 for the non-adaptive system.

Indexed as

Adaptive single photon emission computed tomography (SPECT)simulation studysystem optimizationtask based assessment of image quality

Identifiers

PMID29276799
PMCPMC5739332

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.